background image

RFID Reader

User Manual

SSA-R2001V

Содержание SSA-R2001V

Страница 1: ...RFID Reader User Manual SSA R2001V ...

Страница 2: ...ity and correctness of the contents in this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Samsung Techwin reserves the right to change the contents of this document without prior notice Warranty If the product does not operate properly in normal conditions please let us know Samsung Techwin will...

Страница 3: ...l the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case immediately disconnect the power source and contact the service center Continued use in such a condition may cause fire or electric shock If this product fails to operate normally contact the nearest service center Never disassem...

Страница 4: ...er or an experienced radio TV technician for help 1 2 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers or other apparatus includi...

Страница 5: ...able Selection INSTALLATION AND EXTERNAL CONNECTION 9 9 Installation 10 Precautions on installation 11 External Connection INITIALIZATION 12 12 Basic Operations OUTPUT FORMAT 13 13 WIEGAND Output 14 RS 232 Output 15 8 Bit Burst Output Format TROUBLESHOOTING 16 16 Troubleshooting PRODUCT SPECIFICATIONS 17 17 Product Specifications ...

Страница 6: ...cators as well as the Piezo buzzer this model is guaranteed to make a stable and correct operation 13 56 MHz MIFARE Contactless Smart Card PIN Reader Compatible with ISO14443 Type A 34 bit Wiegand RS 232 Data Output 8 Bit Burst Output Format supported Numeric keypad with backlighting for night operation Control of External LED Indicators Control of External Buzzer Tamper Switch Reverse Polarity Pr...

Страница 7: ...tatus of the system operation 2 Keypad Used to enter the ID password 3 Tamper Switch A tamper switch to detect falling from the wall 4 Connection Cable Used to connect to the power source or I O cable 5 Buzzer Piezo buzzer 6 Fixing Hole Fixing hole for wall mounting SSA R2001V 3 5 6 4 ...

Страница 8: ... LED Control Green LED Control Yellow LED Control Orange LED Control Gray Buzzer Control BUZZER Control Blue Tamper Switch COM Tamper COM Pink Tamper Switch NC Tamper NC Light yellow CABLE SELECTION Item Cable Type Cable Type 1 Power DC12V Belden 9409 18 AWG 2 Conductor Unshielded Belden 9409 18 AWG 2 Conductor Unshielded 2 Card PIN data Wiegand Control Signal LED BUZZER TAMPER Belden 9512 22 AWG ...

Страница 9: ...0 62 30 72 30 72 80 80 60 100 80 Ø1 50 Ø 1 5 0 Ø1 00 40 00 Ø 1 0 0 installation and external connection INSTALLATION See Figure 1 to drill 6 32 holes and 1 2 holes totally 4 into the wall Tighten the four screws to secure the product to the wall With the provided 3mm hex wrench fix the outer case to the product 1 2 3 6 32 or M3 Screws Reader Module Bezel 3mm Hex Wrench 6 32 hole 4cm 4 35cm 8 7cm 4 ...

Страница 10: ...pacer between the metal wall and the reader as shown below IF INSTALLING MORE THAN ONE READER SIDE BY SIDE OR FRONT AND BACK If you install more than one reader side by side or front and back the read range may be reduced In this case if you present a card to one reader the other reader may recognize the same card meaning both readers read the same card simultaneously To avoid this problem keep at...

Страница 11: ...tripes to control the red indicator see page 12 Buzzer Control Enables you to turn on or off the buzzer To control the buzzer connect the blue line to the controller s output relay see page 12 Tamper Control Connect the COM port Pink line of the product s tamper switch to GND connect the NC port Light yellow of the tamper switch to the input port of the controller RS 232 Connection Connect to the ...

Страница 12: ...the I O settings of the controller refer to the user manual of the controller To control the orange indicator connect the gray line to NO of the controller Buzzer Control Connect the buzzer control input line blue to the NO port of the controller relay output and GND to the COM port You can configure the I O settings of the controller so that it beeps If the product continues to beep it means that ...

Страница 13: ... output format WIEGAND OUTPUT Timing Diagram Data Format 34 bit Bit 1 Even Parity bit 2 bit 17 Bit 2 Bit33 4 byte ID Number Bit 34 Odd Parity bit 18 bit 33 100us 1ms DATA 0 DATA 1 1 2 3 5V 0V 0V 5V 0 LOGIC 1 1 1 0 0 n 2 n 1 n n 34 or26 ...

Страница 14: ...ar END 0x03H LRC Check the following settings Baud Rate 9600bps Data Bit 8 Parity Bit None Stop Bit 1 LRC This is the result of XOR operation of each byte from Start to End M Mark 1 Space 0 15V LSB 0 1 1 0 0 0 0 0 0 MSB 3V 3V 15V 0V Data packet corresponding to ASCII character A Start Bit 8 Data Bits Indeterminate Region 2 Stop Bits ...

Страница 15: ...UTPUT FORMAT 8Bit Burst Output Format Keypads Binary Hexa Keypads Binary Hexa 0 11110000 F0 6 10010110 96 1 11100001 E1 7 10000111 87 2 11010010 D2 8 01111000 78 3 11000011 C3 9 01101001 69 4 10110100 B4 ESC 01011010 5A 5 10100101 A5 ENT 01001011 4B ...

Страница 16: ...nected to one adaptor make sure that the adaptor should be large enough to cover the current consumption multiplied by the reader count 2 Even with a large adaptor enough to supply adequate power if the power cable is not a dedicated line such as communication line or UPT cable or if it s so long to cause power loss you d better replace it with a dedicated line or reinforce it 3 If the problem per...

Страница 17: ...isposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system Correct Disposal of This Product Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate c...

Страница 18: ...63 400 TEL 82 70 7147 8740 60 FAX 82 31 8018 3745 SAMSUNG TECHWIN EUROPE LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey UNITED KINGDOM KT16 OPS TEL 44 1932 45 5300 FAX 44 1932 45 5325 SAMSUNG TECHWIN AMERICA Inc 1480 Charles Willard St Carson CA 90746 UNITED STATES Tol Free 1 877 213 1222 FAX 1 310 632 2195 www samsungcctvusa com SALES NETWORK ...