SETUP SCREEN
Specify the record conditions.
Record 1 fps forcibly : Only one frame per second will be recorded regardless of
the existing record profile.
Overwrite : If the Micro SD memory is full, this will delete old data and store new
data in replacement.
Pre-alarm duration : Specify the time point before the occurrence of the alarm;
starting from the time point, the images will be transferred. You can specify up to
5 seconds before the occurrence of the alarm.
Post-alarm duration : Specify the time point after the occurrence of the alarm; to
the specified time point, the images will be transferred. You can specify up to 120
seconds after the occurrence of the alarm.
When done, click [
Apply (
)
].
Alarm input
You can set the alarm input type, activation time, and operation mode.
From the Setup menu, select the
<
Event (
)
> tab.
Click <
Alarm input
>.
Specify an input device.
Type
Normal Open : It is normally open,
but if it is closed, an alarm will be
triggered.
Normal Close : It is normally
closed, but if it is open, an alarm
will be triggered.
Specify the <
Activation time
>.
Always : Always check if an alarm occurs. It activates in operated mode when the
alarm occurs.
If set to Always, the activation time cannot be changed.
Only scheduled time : Check if an alarm occurs at a specified day of the week for
a specified time period. It activates in operated mode when the alarm occurs.
[