18_
installation & connection
installation & connection
`
camera wiring interface Board
For the camera wiring, please refer to the picture below.
J
`
Select Normal Open in the setup menu.
-
The sensor input is activated during a short for contact type, or when it is at “Low” level for
the active type.
`
Select Normal Close from the Setup menu.
-
The sensor input is activated when open for the contact type or when in high impedance
state (open collector) for the active type.
`
The maximum power capacity of the alarm outputs is DC +40V and 80 mA.
`
When connecting alarm input and output cables, be sure to connect one cable to each
terminal respectively.
`
To connect products over the camera’s capacity, please use an additional relay device.
`
Connecting the power connector and GND incorrectly to the alarm out port may lead to fire
and damage the camera.
AUDIOOUT
-L
AUDIOIN
IN1
IN2
IN3
IN4
GND
OUT1
OUT2
Alarm
ETHERNET
Camera’s
internal
Sensor
input
Audio
IN
Audio
OUT
AC24V 2.5A
Power Input
Ground
Power Supply
3.3V
Alarm Input
Sensor
GND