alarm output setup
1.
From the Setup menu, select the
<
event ( )
> tab.
2.
Click <
alarm output setup
>.
3.
Set the camera’s type of alarm output.
`
If you change the alarm output type, the alarm
out button on the monitoring page and alarm
output type displayed on Event Setup page will
be changed accordingly.
•
Type
- Normal open : Considers “Open circuit” status of the sensor or alarm input device
as normal, and triggers alarm event if becomes “Closed circuit” status.
- Normal close : Considers “Closed circuit” status of the sensor or alarm input device
as normal, and triggers alarm event if becomes “Open circuit” status.
4.
Set the alarm output button.
This setup is for the alarm output button in the monitoring page.
•
Mode : Sets the alarm output method.
`
There is difference between operations when clicked alarm output button while disabled.
- Pulse : It is activated during the time period specified by the duration (switching
interval) and then becomes inactive automatically.
- Active/Inactive : It maintains as activated until the user clicks the button again to
make it inactive.
•
Duration : Set the alarm duration that maintains activated if the mode is set to
pulse, from 1 to 15 seconds.
5.
When done, click [
apply (
)
].
English
_125
●
Setup
Screen
Содержание SND-5084R
Страница 1: ...NETWORK CAMERA User Manual SND 5084R SNO 5084R SNV 5084R ...
Страница 15: ...English _15 overview Components a AU DI O OU T AU DI O IN k l m n j i f g h e cd b ...
Страница 23: ...English _23 overview Components AC 24V DC 12V RE SE T VID EO F W A F T N a c b d efg h j i ...
Страница 142: ...appendix Product Overview SND 5084R Unit mm inch 142_ appendix 118 4 65 Ø 132 1 5 2 Ø 97 3 82 107 6 4 24 ...
Страница 144: ...appendix SNV 5084R Unit mm inch 144_ appendix 69 5 2 74 118 5 4 67 Ø 160 6 3 Ø 100 3 94 ...