Smart codec setup
Set a desired area of the video incoming from the camera as ROI area and specify the
detection sensitivity for the area.
1.
From the Setup menu, select the
<
Video & Audio (
)
> tab.
2.
Click <
Smart codec setup
>.
3.
Select ROI Area.
•
Face detection : Active if a face is
recognized on the monitoring screen.
J
`
You can detect max 35 faces on the
screen at the same time.
`
The minimum size of detectable face
is 45x45 (horizontal x vertical) pixels
for the given max resolution. But there
may be some errors depending on the
characteristics of your face or lighting.
•
Manual : Specify the ROI area to monitor manually.
4.
Set the image quality.
The ROI area will be displayed in the specified quality.
5.
If manually specifying the ROI area, select a desired area with the mouse pointer and
drag it as much as you want.
`
You can specify up to 5 distinct areas.
6.
To cancel all the settings for the area, click the [
Clear (
)
] button.
7.
When done, click [
Apply (
)
].
J
`
The Smart codec will not be active if it is set to <
Off
> in <
Video profile
>. (page 72)
`
Go to <
Event
>
<
Event setup
>
<
Face detection
> and change it to <
Enable
> to set the
desired area for facial detection.
English
_91
●
SETUP SCREEN
Содержание SNB-600
Страница 1: ...NETWORK CAMERA User Manual SNB 6003 SNB 6004 SND 6083 SND 6084 ...
Страница 21: ...English _21 OVERVIEW Components b c d h e f g a AU DI O IN AU DI O OU T AU DI O IN AU DI O OU T jk l i ...
Страница 24: ...overview 24_ overview Components c b g d e f a AU DI O IN AU DI O OU T ij k h ...
Страница 145: ...SND 6083 SND 6084 Unit mm inch 118 4 65 Ø 132 1 5 2 Ø 97 3 82 107 6 4 24 English _145 APPENDIX ...
Страница 173: ......