COLOR DOME CAMERA
User’s Manual
28
COLOR DOME CAMERA
User’s Manual
29
●
The image on the screen is dark.
▶
Adjust the contrast feature of the monitor.
▶
If you have an intermediate device, set the 75
Ω
/ Hi-z properly.
●
The camera is not working properly, and the surface of the camera is hot.
▶
Check that you have properly connected the camera to an appropriate power source.
●
The DAY/NIGHT menu does not work.
▶
Check that AGC of EXPOSURE SETUP menu is ‘OFF’.
●
The SENS-UP function does not work.
▶
Check that AGC of EXPOSURE SETUP menu is ‘OFF’.
▶
Check that SHUTTER of EXPOSURE SETUP menu is ‘A.FLK’
.
●
The Motion Detection function does not work.
▶
Check that MOTION DET of SPECIAL SETUP menu is ‘OFF’.
●
Color is not correct.
▶
Check the setting of WHITE BAL SETUP menu .
●
The screen flickers continually.
▶
Check that direction of camera turns toward the Sun.
●
RS-485 communication fails.
▶
Check the polarity between
RS-485 Control Port and RS-485 cable.
▶
Check the RS-485 Communication establishment initial value
▶
We recommend that you make ground connect between camera and controller in order to maintain
safety communication control.
… … ………
When the SPECIAL menu screen is displayed, press the Function Setup switch so
that the arrow indicates ‘COMM ADJ’.
… … …
Set up the mode using the Function Setup switch.
- CAM ID : Determines the camera's identification number (between 0 and 255).
- BAUD RATE : You can select 2400/4800/9600/19200/38400/57600 bps.
- UART MODE : You can select NONE, EVEN or ODD for the parity bits.
- RET PKT : Determines whether to send a command back to the controller device when a
communication control command is sent to the camera.
- DISP CAM ID : Display camera title on top left corner of the screen.
Operating Your Camera
Press the Function Setup switch in the EXIT menu to save the current settings and exit the
MAIN SETUP menu.
LANGUAGE : You can select the menu language according to your requirements.
RESET : Resets the camera settings to the factory defaults. Communication
status and language is not initialized.
RETURN : Select this to save the SPECIAL menu settings and return to the MAIN SETUP
menu.
EXIT
If you have trouble operating your camera, refer to the following table. If the
guidelines do not enable you to solve the problem, contact an authorized
technician.
* RS-485 Communication establishment initial value
Item
Camera ID
BAUD RATE UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL (TRX+)
485+
( - ) CONNECTION TERMINAL (TRX-)
485-
●
Nothing appears on the screen.
▶
Check that the power cord and line connection between the camera and monitor are fixed properly.
▶
Check that you have properly connected VIDEO cable to the camera VIDEO output jack.
●
The image on the screen is dim.
▶
Is lens stained with dirt? Clean your lens with soft, clean cloth.
▶
Set the monitor to proper condition.
▶
If the camera is exposed to too strong light, change the camera position.
Troubleshooting
Dimension
Ø141.2
R48
108mm
105.5mm