2-1-9. Camera
Camera does not work
Connect the connection
Of HDC300
NO
Connect the HDC300
(Cam connector)
Check the condition of
Soldering(F300,F301
F302,F303)
Resolder or change
U504
YES
Check U504
Pin #2, 3
≒
2.5V &
Pin #4 of HDC300(MCLK)
≒
24.5MHz
Check the UCP100
(MSM6250A)
Resolder or change
Check U504
Pin #9
≒
2.8V
Pin #10
≒
1.5 V
END
YES
YES
YES
YES
NO
NO
NO
Pin #6 of HDC300(PCLK)
≒
24.5MHz?
Change the Camera