SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
9-15
9-9. Back Light (for Color Main LCD)
Is LCD Contrast set on high
level in the Menu?
Set LCD Contrast on high level
END
No
Yes
Yes
Backlight does not work
HDC600 PIN 23 = H ?
Resolder HDC600 or change PBA
No
Yes
Содержание SGH-E250D