COLOR CCD CAMERA
User’s Manual
12
COLOR CCD CAMERA
User’s Manual
13
• Connect the power once the installation is complete.
• The wire is polarized. Match '+' and '-' terminals properly.
Notes
• MD(Motion Detection) Output Signal Level(less than 10mA)
• When using the MD function, the 'GND' should be connected to the frame ground.
• Do not simultaneously connect the RS-485 (+) (-) communication line when you use
voltage control ZOOM and FOCUS, using the RECEIVER BOX (SRX-100B).
Notes
Connection
The camera can be controlled by using external controllers like a Remote controller.
(RS-485 Communication)
SCC-3100A
SCC-101
8-Pin CABLE ASSY
Connector Function
Signal Level
I/O
ZOOM
Tele
I
Wide
FOCUS
Far
I
Near
COM
-
MD
O
EX DN
DAY mode: D&N terminals must be OPEN to external signals.
(Do not input voltage)
NIGHT mode: D&N terminal must be connected to the ground
I
There is motion
+3.0V
There is no motion
0V
5±0.5sec
← →
COM
- 6V ~ -12V
COM
+6V ~ +12V
COM
- 6V ~ -12V
COM
+6V ~ +12V
COM
* 8P Control Terminal Configuration
Connecting to 8P Control Terminal
Connecting to Power
DC Power Type (DC 12V, 500mA)
Use DC 12V/500mA power source for SDZ-370N/P.
Power Input Terminal
Number Name
Cable color Description Number Name
Cable color
Description
1
ZOOM
ORANGE
-
5
GND
BLUE
-
2
FOCUS WHITE/ORANGE
6
EX DN
WHITE/BLUE
External D/N
3
COM
GREEN
7
485+
BROWN
RS-485 communication
4
MD OUT WHITE/GREEN
8
485-
WHITE/BROWN RS-485 communication
* Match the communication setup between devices when you use the wired controller
(SCC-101) or SCC-3100A.
• Contact an authorized
technician for
inspection.
Notes
ITEM
SCC-101(fixed) SCC-3100A(Factory Default)
MODE
Serial
Serial
Data Bit
8 bit
8 bit
Bit/Sec
9600bps
9600bps
Parity
EVEN
NONE
CAM ID NO.
0
1~255
RETURN PACKET
ENABLE
See the SCC-3100A manual