4. Alignment and Troubleshooting
4.2.3. Image quality problem
1)
Vertical Black Line and Band
Description : Straight thin black vertical line occurs in the printed image.
Check and cause
Solution
•
Damaged develop roller in the toner cartridge.
Deformed Doctor-blade or cleaning-blade.
•
Scratched surface of the charge roller in the toner
cartridge.
Replace the toner cartridge.
Partly depression or deformation on the surface of the
transfer roller.
Replace the transfer roller.
2)
Vertical White Line
Description : White vertical voids occurs in the printed image.
Check and cause
Solution
Foreign matter stucks onto the window of internal lenses of
LSU mirror.
Clean the LSU window with recommended cleaner (IPA).
Clean the window with a clean cotton swab.
The life of the toner cartridge has been expired
Replace the toner cartridge.
Some foreign substances are on the window of the toner
cartridge frame.
Remove the foreign matter of the exposure window.
If the fuser is defective, voids occur periodically at the top
of a black image.
Reinstall the fuser unit.
Copyright© 1995-2011 SAMSUNG. All rights reserved.
4-43