82_
functional description
functional description
English
English
_ 83
FUNCTIONAL DESCRIPTION
As shown in the picture above, the Alarm Input must be entered with the Open or
Closed switch signals. Supplying power without entering the signals may damage the
product.
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously
activated, the alarm with the highest priority activates before the others. Once
the alarm is canceled, the next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm.
Available sequence actions are Home, Preset, Swing, Group, Tour, Trace and
A.Pan.
For the Auto Pan settings, the fi rst number under the Number menu indicates
the speed while the second is the Tilt angle. (Refer below.)
MD Dwell Time :
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time
performs the Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a
selected preset location, the camera pauses the sequence action operation and
starts monitoring the location instead for a duration that is set under the MD
Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts
the monitoring operation and then resumes the sequence action.
M
•
•
❋
•
ALM
MOD P
SEQ
NO
IN 1
NO
1
A.PAN
20/20
IN 2
NC
2
A.PAN
20/20
Tilt Angle
Speed
Alarm Output
Main Menu/Alarm Setting/Alarm Output
Setting 1,2 :
1, 2, Motion, and Support Device indicate
alarm input ports, Motion Detection, and
support device input. A total of 4 alarms,
Motion Detection, and support devices can be
set up to output alarms. 1 alarm output port
can be used for more than 2 alarm inputs and
Motion Detection.
Timer 1,2 :
Enables selecting an Alarm Output method.
On : Retains an alarm output for a set
duration from a minimum of 1 second
to a maximum of 60 minutes upon the
alarm occurrence.
Momentary : Retains an alarm output only
until the alarm is canceled.
The Alarm Output is equipped with a relay
circuit. The operation of the alarm output port
is as shown in the diagram below.
Connecting the power connector and GND incorrectly to the NC/NO and COM ports
may cause a short circuit and fi re, damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the
camera’s lifespan and damage it.
►
•
•
-
-
❋
M
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Alarm Setting
Alarm Enable
OFF
Alarm Input
Alarm Output
MD Dwell Time
OFF
Alarm Output
Setting 1
þ
1
þ
2
þ
MD
þ
AUX
Setting 2
þ
1
þ
2
þ
MD
þ
AUX
Timer 1
OFF
Timer 2
OFF
OUT Off 1
OUT Off 2
NO
COM
NC
Alarm Out OFF
NO
COM
NC
Alarm Out ON