S3F84B8_UM_REV 1.00
6 INSTRUCTION SET
6-14
6.3.2 ADD — ADD
ADD
dst,src
Operation
: dst
dst + src
The source operand is added to the destination operand. Their sum is stored in the destination.
The contents of source remain unaffected. Two’s-complement addition is performed.
Flags
:
C
: Set if there is a carry from the most significant bit of the result; cleared otherwise.
Z
: Set if the result is “0”; cleared otherwise.
S
: Set if the result is negative; cleared otherwise.
V
: Set if arithmetic overflow occurred, that is, if both operands are of the same sign and the result
is of the opposite sign; cleared otherwise.
D
: Always cleared to “0”.
H
: Set if a carry from the low-order nibble occurred.
Format
:
Bytes Cycles
Opcode
(Hex)
Addr Mode
dst src
opc
dst | src
2
4
02
r
r
6 03
r
lr
opc
src
dst
3
6
04
R
R
6 05
R
IR
opc
dst
src
3
6
06
R
IM
Examples
:
Given R1 = 12H, R2 = 03H, register 01H = 21H, register 02H = 03H, and register 03H = 0AH:
ADD
R1,R2
R1 = 15H, R2 = 03H
ADD R1,@R2
R1 = 1CH, R2 = 03H
ADD 01H,02H
Register 01H = 24H, register 02H = 03H
ADD 01H,@02H
Register 01H = 2BH, register 02H = 03H
ADD 01H,#25H
Register 01H = 46H
In the first example, destination working register R1 contains the value 12H and source working
register R2 contains the value 03H. The statement “ADD R1,R2” adds 03H to 12H, leaving the
value 15H in register R1.