background image

Fast Track Troubleshooting 

IMPORTANT SAFETY NOTICE

 – 

“For Technicians Only”

  This service data sheet is 

intended for use by persons having electrical, electronic, and mechanical experience 
and knowledge at a level generally considered acceptable in the appliance repair trade.  
Any attempt to repair a major appliance may result in personal injury and property 
damage.  The manufacturer or seller cannot be responsible, nor assume any liability for 
injury or damage of any kind arising from the use of this data sheet. 

Models Covered: 
RF265AA**/XAA   
RF265AB**/XAA   
RF265AC**/XAA           
French Door Refrigeration 

Press Freezer button a 
third time to Force Defrost 
for Fridge & Freezer, 
measure defrost voltages  
at main  PCB 

Wait 5 seconds between button pushes

 

Press the Freezer button 
a second time to Force 
Fridge Defrost. Measure 
defrost voltage at main 
PCB. 

Press the Freezer button 
one time at the Test Mode 
to Force Compressor Run. 
Measure fan and  compres-
sor voltage at main PCB. 

Self Diagnosis: Press the Pwr Freeze—Pwr 
Cool buttons simultaneously for 8-12 seconds 
(No sound when both buttons are pressed at 
the same time) until the display quits blinking. 
Release the buttons and read Fault Codes. 
This will also cancel the Fault Mode created by 
self-diagnosis at power up. 

 

Forced Mode: Press the Pwr Freeze– Fridge 
buttons simultaneously for 8-12 seconds 
(No sound when  both buttons are pressed 
at the same time) until the display beeps 
and goes blank.

 

Compressor 

 Condenser 

Side Cluster 

 Hot Pipe

 

Dryer 

 R Capillary 

 R Evaporator 

 F Evaporator 

  

Suction Pipe 

 Compressor

 

Publication #  tsRF265AA   Revision Date 08/12/2010

 

Sealed System 

Component Value Chart 

Sales Mode,  No Compressor Operation 

Press Power Freeze & Freezer temp buttons      
simultaneously for 3 sec ( you will hear a “Ding 
Dong”) to remove or put into Sales Mode. When   
in the Sales Mode the Display will show "OF" "OF" 

Removing power will not cancel this mode.

 

Refrigerant Charge                      

R134a     5.64 oz.

 

Component

Resistance Wattage Voltage

Freezer Defrost Heater

60

240

120vac

Fridge Defrost Heater

120

120

120vac

French Mullion Heater

1323

10

120vac

Fill Tube Heater

1323

10

120vac

Sensors

2.5k

-89k

N/A

1~4.5vdc

Fans

N/A

N/A

7~12vdc

NOTICE:                          

RF265AB**   Parts Change: 

Refer to bulletin. Freezer 

Door Handle parts

 

 

 

1

Содержание RF265AA**/XAA

Страница 1: ...s simultaneously for 8 12 seconds No sound when both buttons are pressed at the same time until the display quits blinking Release the buttons and read Fault Codes This will also cancel the Fault Mode created by self diagnosis at power up Forced Mode Press the Pwr Freeze Fridge buttons simultaneously for 8 12 seconds No sound when both buttons are pressed at the same time until the display beeps a...

Страница 2: ...it is lower than 1 5Ԭ for more than 5 minutes it will do a harvest with or without ice in the tray then fill with water 58 minutes after water is supplied to the Ice Tray the Ice Maker Sensor temperature will be checked When the Ice Maker Sensor maintains lower than 1 5Ԭ for 5 minutes it completes the harvest if the ice bin is not sensed as full Filling the tray After the water fill is completed t...

Страница 3: ...nsor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor between 4 5V 1 0V F SENSOR Freezer Compartment Sensor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor between 4 5V 1 0V F DEF SENSOR Freezer Room Defrost Sensor Error open or short circuit conn...

Страница 4: ... 5 3 12 VDC Yel Blk CN78 7 8 Pantry Disp 9 11 Blu Wht 12vdc 10 11 Sw input Prp Wht 5vdc CN50 Display 4 6 Org Pnk 13vdc 5 6 Yel Pnk 5vdc CN32 Sensor 1 4 Ambient Sensor Wht Wht 1 2 2 vdc CN90 Ice Maker 1 2 Eject Motor Red Blk 12 4 3 Ice Sensor Wht Wht 2 3 5 8 Test Switch Gry S Blu 6 8 5vdc Blu 7 8 Hall IC Out Prp S Blu 8 GND S Blu CN30 Sensors Switches 1 5 Freezer Dr Sw Blk Gry 2 CN50 7 R Door Sw Pr...

Страница 5: ...e resistance Ohm DISPLAY operating part PANTRY DISPLAY operating part ICE MAKER operating part SWITCH SENSOR part SMPS power part PANTRY ROOM DAMPER operating part FAN MOTOR operating part AC load operating part HEATER COMP ETC AC INPUT AC INPUT AC INPUT AC INPUT AC INPUT 240 120 10 10 55 220 110 441 1323 5290 1323 5290 55 220 102 407 1323 5290 RF265AA XAA RF265AB XAA RF265AC XAA 5 ...

Отзывы: