Samsung OHN Series Скачать руководство пользователя страница 1

OHN
OH85N/(LH85OHNSKGB/**)
OH85N-D(K)/(LH85OHNDKGB/**)
OH85N/(LH85OHNSLGB/**)

Follow the instructions provided in this guide when installing the product.
Samsung will not provide warranty coverage for problems that may arise as a result of failure to follow the guide.
The color and shape of the product may vary. In addition, instructions in the installation guide may change without prior notice when 

necessary to improve the product.

Outdoor 

Installation Guide

Содержание OHN Series

Страница 1: ...lling the product Samsung will not provide warranty coverage forproblems that may arise as a result of failure to follow the guide The colorand shape of the product mayvary In addition instructions in...

Страница 2: ...mount 11 02 Enclosureunitdesignguide Air flow direction 12 Inlet and outlet types 12 Total open area of the ventilation holes and ratio 13 Precautions for enclosure unit designing 13 Enclosure unit p...

Страница 3: ...t angle 27 Clearance for installation 28 02 Enclosureunitdesignguide Air flow direction 29 Inlet and outlet types 29 Total open area of the ventilation holes and ratio 30 Precautions for enclosure uni...

Страница 4: ...ir flow direction 46 Inlet and outlet types 46 Total open area of the ventilation holes and ratio 47 Precautions for enclosure unit designing 47 Enclosure unit partition design 48 Single enclosure uni...

Страница 5: ...KGB OH85N LH85OHNSKGB...

Страница 6: ...block off at least 50 of the solarheat the unit receives Installingtheprotectionglass Samsung guarantees the product swaterand dust resistance performance IP56 This guarantee however does not coveran...

Страница 7: ...t maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When installed in beach area make sure the display is placedwhere seawatercan...

Страница 8: ...l oran obstacle up to15 Contact Samsung CustomerService Centerforfurtherdetails 15 Wall or obstacle Wall or obstacle 50 mm ormore 50 mm ormore Landscape Portrait Do not use this model installed on a c...

Страница 9: ...at due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partition Clearanceforbuilt ininstallation When installing built in to thewall...

Страница 10: ...n obstacle orawall maycause a malfunction ora problemwith the product Clearance 200 mm ormore Remove anyobstacles nearthe inlet and outlet that mayaffect airflow If the unit is subjected to excess hea...

Страница 11: ...e holes Mount holes 15 mm Mount hole M8 bolt Portraitinstallation Do not use the 4 holes at the bottom as theyare NOTmount holes Use M8 bolts in the 8 holes formounting 4 at the top and 4 in the cente...

Страница 12: ...discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Back Sideview Airinlet Airoutlet Inletandoutlettypes Ventilation opening ratio...

Страница 13: ...mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area ofVentilation holes 12 800 mm x100 79 Total Area of theVentilation 16 1...

Страница 14: ...specifications to keep discharged hot airfrom flowing back into the inlet Airinlet Total open area of theventilation holes 63000 mm ormore Ventilation opening ratio of total opening 70 ormore Airoutle...

Страница 15: ...ouble sided design is not supported Toadddevicessuchasamediaplayer If installing otherdevices such as a media player use partitions to make sure theyare installed separatelyfrom the product Heat from...

Страница 16: ...Use the crane to move the product Landscape Portrait 3 When the product has been brought to the installation site unfasten and remove the Bracket Hang and bolts 4 Place Cover Caps in the holes on the...

Страница 17: ...aning Cleaningtheprotectionglass Consult the manufacturerof the protective glass forcleaning The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protect...

Страница 18: ...keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and othermaterials more than 20 Remove powerbefore cleaning Use an industrial...

Страница 19: ...outingcables Route cables connected to the product in a mannerthat keeps them awayfromwater The guide forOH85N LH85OHNSKGB onlyapplieswhen the product is usedwith an enclosure unit that has a protecti...

Страница 20: ...ness foreach 7 x1 Insert the 7 cable 5 5 x 6 Insert the 5 5 cable 3 x 2 Insert the 3 cable 8 5 x1 Insert the 8 5 cable Insert the appropriate cable into the hole fromwhich the silicone barwas removed...

Страница 21: ...n the screws Differentpowercablecolorsbycountry When connecting an external powercable be sure to match the colors of itswireswith those of the 3wires inside the product s powercable The meaning Neutr...

Страница 22: ...ill lessen the protection ofyourproduct against waterand mayresult in a malfunction due towaterdamage whichwill not be covered bythewarranty Silicone bar Aftercomplete cabling ensure that there is no...

Страница 23: ...utionswhenreplacingparts This product is designed to resistwaterand dust Do not disassemble the product If disassemblyis necessarydue to a malfunction contact the service center The guide forOH85N LH8...

Страница 24: ...OH85N D K LH85OHNDKGB...

Страница 25: ...glass that can block off at least 50 of the solarheat the unit receives Installingtheprotectionglass Samsung guarantees the product swaterand dust resistance performance IP56 This guarantee however do...

Страница 26: ...ng the inlet oroutlet maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When installed in beach area make sure the display is pla...

Страница 27: ...dscape Contact Samsung CustomerService Centerforfurtherdetails Wall or obstacle 50 mm ormore Portrait Do not use this model installed on a ceiling floor ortable The guide forOH85N D K LH85OHNDKGB only...

Страница 28: ...the unit is subjected to excess heat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty 250 mm ormore 200 mm ormore Floor Hingeinstallationguide Referto the...

Страница 29: ...erature and discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Label rating Inletandoutlettypes Ventilation opening ratio forairin...

Страница 30: ...09 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area ofVentilation holes 12 800 mm x100 79 Total Area of theVentilation 16...

Страница 31: ...Open area of EnclosureVentilation holes 80 000 mm ormore Ventilation opening ratio of total opening 70 ormore Design the locations of the enclosure unit inlet and outlet to match the locations of the...

Страница 32: ...Bracket Hang and bolts M8 x L23 contactyourproviderorSamsung 2 Use the crane to move the product Portrait 3 When the product has been brought to the installation site unfasten and remove the Bracket...

Страница 33: ...leaning Cleaningtheprotectionglass Consult the manufacturerof the protective glass forcleaning The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclosure that has a protec...

Страница 34: ...ithwater keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and othermaterials more than 20 Remove powerbefore cleaning Use an ind...

Страница 35: ...cables connected to the product in a mannerthat keeps them awayfromwater Route cables awayfrom the inlet and outlet The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith an enclos...

Страница 36: ...the main display Silicone bar Remove the appropriate silicone barforthe thickness of the cable to connect Insert the appropriate cable into the hole fromwhich the silicone barwas removed Once all cabl...

Страница 37: ...om of the main display Close the auxiliarydisplay completely then fasten the brackets on both sides of the product Differentpowercablecolorsbycountry When connecting an external powercable be sure to...

Страница 38: ...7 5 cables 5 5 hole Forinserting 5 5 6 cables 3 hole Forinserting 3 3 5 cables Do not remove silicon barswhere there is no cable connection Thiswill lessen the protection ofyourproduct against wateran...

Страница 39: ...resistwaterand dust Do not disassemble the product If disassemblyis necessarydue to a malfunction contact the service center The guide forOH85N D K LH85OHNDKGB onlyapplieswhen the product is usedwith...

Страница 40: ...OH85N LH85OHNSLGB...

Страница 41: ...t Blockedventilation due to snowordust covering the inlet oroutlet maycause a malfunction The product can be used in a train orsubway station The product is designed to keep out iron dust When install...

Страница 42: ...ons This product can be installed in a tilted position on averticalwall oran obstacle up to15 Contact Samsung CustomerService Centerforfurtherdetails 15 Wall or obstacle Wall or obstacle 50 mm ormore...

Страница 43: ...at due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty Sideview Wall orobstacle Partition Clearanceforbuilt ininstallation When installing built in to thewall...

Страница 44: ...g the product Excessive heat due to the use of the enclosure unitwith an obstacle orawall maycause a malfunction ora problemwith the product Clearance 200 mm ormore Remove anyobstacles nearthe inlet a...

Страница 45: ...mm holes afterpassing through the mount M8 bolts are not included Guide holes Mount holes 15 mm Mount hole M8 bolt Portraitinstallation Do not use the 4 holes at the bottom as theyare NOTmount holes...

Страница 46: ...oling fans to take in outside airto lowerthe internal temperature and discharge the hot air When installing the product remove anyobstacles nearthe airinlet and outlet that mayaffect airflow Back Side...

Страница 47: ...Ventilation opening ratio Total Area of theVentilation 181 x 89 16 109 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ratio Total open area o...

Страница 48: ...gleenclosureunit Design the enclosure unit according to the following specifications to keep discharged hot airfrom flowing back into the inlet Airinlet Total open area of theventilation holes 63000 m...

Страница 49: ...sure unit add partitions between the products to keep the airpaths separated Referto the Total open area of theventilation holes and ratio Page 47 Make sure there is no gap between the partitions and...

Страница 50: ...side Outlets of the enclosure unit should be on the side Add partitionswithout anygap as shown in the image below to completelyseparate the inlet and outlet Secure at least 400 mm of clearance between...

Страница 51: ...ase the Bracket Hang and bolts M8 x L23 contactyourproviderorSamsung 2 Use the crane to move the product Landscape Portrait 3 When the product has been brought to the installation site unfasten and re...

Страница 52: ...oth dampenedwithwatertowipe off the surface Magic Glass Wipe off the surface periodicallywith a clean soft cloth dampenedwithwaterorglass cleaner cleaning cycle within1 month Fordirt that cannot be re...

Страница 53: ...a clothwith a small amount of ethanol based cleaner Ifwashingwithwater keep the pressure below0 5 bar Check once every6 months and clean the inlet and outlet if theyare covered blocked bydust and oth...

Страница 54: ...rdingtheCover Cap Place Cover Caps in the holes on the top and sides Cover Caps foryourproduct are found enclosed in the package Cautionswhenroutingcables Route cables connected to the product in a ma...

Страница 55: ...he cable to connect Different hole sizes and corresponding cable thickness foreach 7 x1 Insert the 7 cable 5 5 x 6 Insert the 5 5 cable 3 x 2 Insert the 3 cable 8 5 x1 Insert the 8 5 cable Insert the...

Страница 56: ...ted part of the cable inside the product Place the back coverand fasten the screws Differentpowercablecolorsbycountry When connecting an external powercable be sure to match the colors of itswireswith...

Страница 57: ...les Do not remove silicon barswhere there is no cable connection Thiswill lessen the protection ofyourproduct against waterand mayresult in a malfunction due towaterdamage whichwill not be covered byt...

Страница 58: ...re to close the coverand fasten the screws to ensure it iswatertight Cautionswhenreplacingparts This product is designed to resistwaterand dust Do not disassemble the product If disassemblyis necessar...

Страница 59: ...Thispageisintentionally leftblank...

Страница 60: ...Thispageisintentionally leftblank...

Отзывы: