OfficeServ 7100
INSTALLATION
TECHNICAL MANUAL
PART 7 MAY 2010
7.26
The OfficeServ 7100 system supports only one dry contact for the common bell. The MISC
port is located on the front panel of the MP10/MP10a.
Figure 7.23 Connecting Common Bells
WARNING
: Do not attempt to connect commercial AC power to these contacts.
1)
After connecting a common bell, you must assign it in MMC 601 to a group as a ring
destination by using the code for common bell.
2)
After wiring to the contact pair, set contacts for continuous or steady operation.
3)
Next, program hunt group to include the common bell.
4)
Assign the trunk to ring the hunt group containing the common bell. Common bell
control can be used with station hunt groups, individual stations and universal answer.
7.2.5 Ring Over Page
When a customer-provided paging system is installed, incoming calls can be assigned to ring
over page. Program the C.O. line or C.O. lines to ring a hunt group. Using MMC 601, assign the
DN number of the Page Output (voice) for the MISC port being used as a member of the
group or as the NEXT PORT for the overflow destination. Other stations may be assigned to
the same group to provide ringing to phones and the paging system at the same time.
MISC
FUNCTION # in MMC 724
DEFAULT
DN
02
361
7.2.6 Connecting OfficeServ Installation Tool
Installation Tool is a computer application that provides various maintenance and
management functions for the OfficeServ 7100. The minimum requirements for a PC running
Installation Tool are as follows:
Dry contact
(For common bell)
Home Page
Table of Contents
Home Page