English 17
Ins
tallation r
equir
ement
s
Electrical requirements
WARNING
To reduce the risk of fire, electric shock, or personal injury:
All ranges
•
Do not use an extension cord or adapter plug with this range.
•
This range must be properly grounded.
•
Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded.
•
Do not modify the plug provided with your range—if it doesn’t fit the outlet, have
a proper outlet installed by a qualified electrician.
•
All wiring and grounding must be done in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70 –
Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 – Latest
Revisions and local codes and ordinances.
•
Wiring diagram is located on the back of the range. (Inside of the cover back wire)
•
This range is equipped with an electronic ignition system that will not operate if
plugged into an outlet that is not properly polarized.
Gas models
•
All gas models are equipped with a power cord with an equipment-grounding
conductor and a grounding plug.
•
A 120-Volt, 60-Hz, AC, approved electrical service with 20-amp circuit breaker or
time-delay fuse is required for all U.S. and Canadian models.
•
Check for ¾-in (1.9-cm) UL-listed strain relief where the power cord comes out of
the range cabinet.
•
Do not reuse a power supply cord from an old range or other appliance.
•
The power cord electric supply wiring must be retained at the range cabinet with
a suitable UL-listed strain relief.
•
A time-delay fuse or circuit breaker is also recommended.
Special gas requirements (gas models sold in massachusetts)
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:
WARNING
Gas leaks may occur in your system, creating a dangerous situation.
– Gas leaks may not be detected by smell alone.
– Gas suppliers recommend you purchase and install a UL-approved gas detector.
Gas detector should be installed in accordance with the manufacturers
instructions.
•
Range must be installed by a qualified plumber or gas fitter by the State of
Massachusetts.
•
A T-handle manual gas valve MUST be installed in the gas supply line to your
range.
•
If a flexible gas connector is used to install your range, multiple flexible gas lines
must not be connected in series.
Install_NX60T9700_BEST_BETTER_AA_DG68-01243A-00_EN.indd 17
2020-03-26 6:41:23
Содержание NX60 8 Series
Страница 26: ...Memo Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_EN indd 26 2020 03 26 6 41 26 ...
Страница 27: ...Memo Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_EN indd 27 2020 03 26 6 41 26 ...
Страница 54: ...Notas Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_MES indd 26 2020 03 26 6 41 09 ...
Страница 55: ...Notas Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_MES indd 27 2020 03 26 6 41 09 ...
Страница 82: ...Notes Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_CFR indd 26 2020 03 26 6 40 51 ...
Страница 83: ...Notes Install_NX60T9700_BEST_BETTER_AA_DG68 01243A 00_CFR indd 27 2020 03 26 6 40 51 ...