18 English
Installation requirements
Installation requirements
Recommended locations for gas piping and electrical outlets
(For models NX58*565***/NX58*560***/NX58*751***)
12”
12”
(30.5 cm)
(30.5 cm)
17” x 2”
17” x 2”
(43.2 cm x 5.1 cm)
(43.2 cm x 5.1 cm)
Gas Floor Area
Gas Floor Area
30” (76.2 cm)
30” (76.2 cm)
Cabinet Opening
Cabinet Opening
Recommended
Recommended
position
position
Recommended
area for 120 V
electrical outlet
on rear wall
17” x 9”
(43.2 cm x 22.9 cm)
Gas Wall Area
Recommended area
for through-the-wall
and through-the-floor
connection of gas pipe
stub and shut-off valve.
Gas requirements
Provide adequate gas supply
This range is designed to operate at a pressure of 5” (13 cm) of water column on
natural gas or 10” (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is
designed.
Do not attempt to convert the appliance from the gas specified in this
manual to a different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use
this range on LP gas, conversion must be made by a qualified LP installer before
attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be
between 5” and 13” (13 cm and 33 cm) of water column.
For LP gas, the pressure supplied must be between 10” and 13” (25 cm and 33 cm)
of water column.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1” (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in
the supply line regardless of whether natural or LP gas is being used.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5” (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.
Install_NX58H56_DG68-00524A-13_EN+MES+CFR.indb 18
Install_NX58H56_DG68-00524A-13_EN+MES+CFR.indb 18
2020-10-13 11:50:31
2020-10-13 11:50:31