English 7
Impor
tant saf
ety inf
ormation
•
Cabinet storage above the surface of the range should be avoided. If cabinet
storage above the range is necessary: allow a minimum clearance of 40 inches
(102 cm) between the cooking surface and the bottom of cabinets; or install a
range hood that projects horizontally a minimum of 5 inches (12.7 cm) beyond
the bottom of the cabinets.
• Locate
the range out of kitchen traffic paths and drafty locations to prevent poor
air circulation.
•
If the range is located near a window, NEVER hang long curtains or paper blinds
on that window. They could blow over the surface burners and ignite, causing a
fire hazard.
Cooktop safety
WARNING
To reduce the risk of fire, electric shock, personal injuries, and/or death, observe
the following precautions.
• Make sure
all burners are off when not using the
range.
• Do not use
aluminium foil to line the grates or
any part of the cooktop. This can cause carbon
monoxide poisoning. Aluminum foil linings may
also trap heat, causing a fire hazard.
• Do not leave
burners unattended on medium or high heat settings.
•
Before igniting the burners,
make sure
all burner caps are properly in place and
all burners are level.
• Always use
the LITE position when igniting the burners and make sure the burners
have ignited. If ignition fails, turn the knob to OFF and wait until the gas has
dissipated.
•
Installation of this range must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest edition. In
Canada, the Natural Gas and Propane Installation Code, CSA B149.1. This range
has been design-certified by ETL according to ANSI Z21.1, latest edition, and
Canadian Gas Association according to CAN/CGA-1.1, latest edition.
Location safety
WARNING
To reduce the risk of fire, electric shock, personal injuries, and/or death, observe
the following precautions.
•
This range is for indoor, household use only.
Do not install
the range in areas exposed to the
weather and/or water.
• Do not install
the range in a place which is
exposed to a strong draft.
•
Select a level, well-constructed floor that can support the range’s weight.
Synthetic flooring, such as linoleum, must withstand 180 °F (82 °C) temperatures
without shrinking, warping, or discoloring.
Do not install
the range directly over
interior kitchen carpeting unless a sheet of ¼ inch plywood or a similar insulator
is placed between the range and carpeting.
•
Select a location where a grounded, 3-prong outlet is easily accessible.
•
If the range is located near a window,
do not hang
long curtains or paper blinds
on that window.
•
Do not block or cover the vents (air openings). The vents allow for air circulation
that is necessary for the range to operate properly with correct combustion.
Blocking or covering the vents may cause incorrect combustion which could
result in gas leaks and fire.
• Make sure
the wall coverings around the range can withstand heat up to 200 °F
(93 °C) generated by the range.
NX58N3315SS_AP_DG68-00773B-01_EN.indd 7
2020-06-18 오후 5:16:16