MMC
50
SYSTEM
TIMERS
Description:
Used to adjust individual timers as necessary. All available timers are described
in the Table of Timers and Values, below.
NOTE: Display shows second as S, millisecond as MS, and minute as MI.
Action
Display
1.
Press
AUTO RDL
and dial
50
ALM R INT :025SEC
2.
Press
LINE1
or
LINE2
to select timer
(e.g. ALM R DUR)
ALM R DUR: 010SEC
3.
Enter new value using KEYPAD(e.g. 005)
ALM R DUR: 005SEC
4.
Press
AUTO RDL
to save and exit
DEFAULT DATA
Se e TABL E OF TIMER S AN D VAL U ES
RELATED MMC
NONE
TABLE OF TIMERS AND VALUES
DISPLAY
DESCRIPTION
DEFAULT
RANGE
ALM R INT
(Alarm ring interval)
Controls the time between ring attempts at a station when alarm
reminder is set.
025S
1-250S
ALM R DUR
(Alarm ring duration)
Controls the length of ring cycle duration when alarm reminder is set
at a station.
010S
1-250S
ARDL INT
(Auto Redial interval)
Controls the time between attempts after Auto Redial is set on a
station.
045S
1-250S
ARDL RELS
(Auto Redial release time)
Controls the duration of a Ring No Answer condition on an auto redial
number dialled before auto redial is automatically cancelled.
045S
1-250MI
CBACK NOA
(Callback no answer time)
Controls the time before the callback is automatically cancelled when a
callback detects Ring No Answer.
030S
100-2500MS
CO CO DIS
(CO to CO disconnect time)
Monitors the duration of an unsupervised conference, external call;
forward or DISA call upon expiring, both trunks are disconnected.
010MI
1-250S
DISA FDG
First digit want time in DISA call
025S
1-250S
DISA IDG
Inter digit duration in DISA call
025S
1-250S
DISA RING
Controls the duration of ringing at the DISA called station before
automatically
transferred to the operator group.
030s
1-250S
DOOR RELS
(Door release time)
Controls the duration of time before the door lock relay is activated.
1500MS
100-2500MS
DOR R OFF
(Door Ring OFF duration)
Controls the duration of ringing at the door ring destination before
automatically cancelling.
030S
1-250S
NX-828
HYBRID KEY SYSTEM
PROGRAMMING
Содержание NX-828
Страница 1: ......
Страница 5: ......
Страница 6: ......
Страница 15: ...NX SERIES HYBRID KEY SYSTEM GENERAL DESCRIPTION 1 8 ...
Страница 16: ......
Страница 42: ......
Страница 73: ......
Страница 80: ...NX 828 HYBRID KEY SYSTEM PROGRAMMING 4 6 ...
Страница 121: ...MMC 45 DEFAULT DATA GROUP 9 ALL TRUNK LINES GROUP 80 89 NONE RELATED MMC NONE NX 828 HYBRID KEY SYSTEM PROGRAMMING ...
Страница 161: ......
Страница 173: ......
Страница 174: ...NX 828 SYSTEM DATABASE FORMS CUSTOMER NAME ADDRESS TELEPHONE NUMBER DATABASE CONTAINS SHEETS ...
Страница 186: ......