background image

Air conditioner

User manual

Wired remote controller MWR-WG00KN

 

Thank you for purchasing this Samsung Product.

 

Before operating this unit, please read this user manual carefully and retain it for future 
reference.

SOL 신규 유선리모컨 LCD 유럽향 IB_EN_DB68-08384A-00_Book_.indd   1

2019-05-16   오후 2:29:12

Содержание MWR-WG00KN

Страница 1: ...ontrollerMWR WG00KN Thank you for purchasing this Samsung Product Before operating this unit please read this user manual carefully and retain it forfuture reference SOL 신규 유선리모컨 LCD 유럽향 IB_EN_DB68 08384A 00_Book_ indd 1 2019 05 16 오후 2 29 12 ...

Страница 2: ...tion 8 Purify function Heating Operation 9 Heat mode Quick Smart Features 9 Auto mode Fan mode Quiet function Sleep function Long Wind function Ventilation ERV Operation 11 Ventilation ERV Operation 11 Operation modes Controlling fan speed E Saverfunction Clean up function Energy Saving Operation 13 Energy Saving Operation 13 Schedule Energy Setting Options 15 Setting Options 15 How to set the Opt...

Страница 3: ...e product or injury You must connect the product with rated powerupon installation Failing to do so may result in problems with the product electric shock or fire Do not install this appliance neara heater inflammable material Do not install this appliance in a humid oily ordusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location wher...

Страница 4: ...ice centre forperiodic inspection Neglecting these periodic inspections can result in malfunctions onlyapplicable to GHP model Do not attempt to repair disassemble ormodifythe product yourself Failing to do so may result in electric shock fire product malfunction or injury CAUTION Do not allowwaterto enterthe product Failing to do so may result in fire or explosion Do not operate the product with ...

Страница 5: ... in each mode as follows Mode Temperature control Auto Cool Dry Adjust by1 C between 18 C and 30 C Fan You cannot control the temperature Heat Adjust by1 C between 16 C and 30 C NOTE The set temperature range available on the remote controller may change depending on the set temperature range that indoor unit supports Controlling fan speed You can select the following fan speeds in each mode Mode ...

Страница 6: ...he indoor units other than 360 cassette when Spot Mid orWide is started as the air flow direction You can select individual air flow direction for each blade when the individual indication appears active on the indoor unit that supports this mode NOTE The displayed flow direction icon may differ depending on the indoor model The current air flow direction persists even if you change the current mo...

Страница 7: ...ing so that cool air does not come out However mild breeze comes out and starts to clean the air in the room During the Wind Free operation the cold air may be intermittently weakened depending on the temperature and humidity in the room But the wind free air currents are maintained and the weakened cold air is immediately recovered consequently keeping the room comfortable During the Wind Free op...

Страница 8: ...urify function is additionally selected while a specific mode is running there is little difference in electricity consumption and operating noise Airpurity level indications The indications are displayed only on the models that support the air purity level display function The air purity levels for PM10 PM2 5 and PM1 0 appear as follows Purity level PM10 PM2 5 PM1 0 Colour Concentration μ m Colou...

Страница 9: ...The heating functions of the Samsung air conditioner keep an enclosed space warm and comfortable Heating Operation Auto mode Use the Auto mode when you want the air conditioner to automatically control the mode Heat or Cool The air conditionerwill provide the most comfortable atmosphere that it can NOTE You cannot change the fan speed While the Cool mode is running the air conditioner produces a s...

Страница 10: ...OTE You can select this function only in the Cool and Heat modes You can control the set temperature fan speed and air flow direction When you select Sleep in Wind Free or Long Wind function the previous function is cancelled Long Wind function Use the Long Wind function to quickly deliver a long reaching air flow NOTE You can select this function only in the Cool Dry and Fan modes You cannot cont...

Страница 11: ...e ventilator ERV Away This mode allows you to operate the ventilator ERV while you are away from home NOTE Only when you select all the options of ventilator ERV you can use the above operation Only available when the wired remote controller is installed If the operation status is changed by another controller the operation mode is cancelled Controlling fan speed You can select the following fan s...

Страница 12: ...ration The ventilator ERV turns On and Off in Quiet Medium mode every 30 minutes Outdooraircooling operation fordifferent temp setting Operates when the View Master is for ERV With the temperature control button the default temperature for E Saver can be set Depending on the set temperature it automatically selects Heat EX or By Pass operation NOTE When the air conditioner is connected individuall...

Страница 13: ... time You can schedule on the weekly basis You can also set the values for day time operation on off scheduled device and operation status operation mode set temperature fan speed Yearly schedule Creates groups for the desired months for scheduling You can schedule up to 8 groups on the yearly basis Holiday Allows you not to make use of the schedule on holidays NOTE Weekly schedule and Yearly sche...

Страница 14: ...perature Heating Setback Temperature After the set time to change the set temperature in the Heat mode the temperature is changed to the set temperature Operation Time Limit When the set time elapses the operation of indoor unit stops It does not operate during the restricted operation hours Setback Controls the indoor unit with 4 different operation patterns Each pattern sets the values for time ...

Страница 15: ...sette SwingON SwingOFF 360cassette Spot Mid Wide Motiondetect sensor SetMotion detectsensor ON OFF OFF Motion detection type IndirectWind DirectWind Indirect Wind Option Usermode Language Differsdependingonthe language Firstvalue forthe language pack Daylight SavingTime Daylight SavingTime ON OFF OFF Unit Day Week Week Month JanuarytoDecember Mar Week 1stto4th Final finalweek F final week Day 1to3...

Страница 16: ...dditional ModeLock Wind Free Lock ON OFF OFF LongWind Lock ON OFF OFF QuietLock ON OFF OFF SleepLock ON OFF OFF ScheduleLock ON OFF OFF Wiredremote controller LED ON OFF ON ButtonMute ON OFF OFF Wireless remote controller ON OFF OFF Currenttime Date 2000to2099 1to12 1to31 2018 01 01 Time 12 Hour 24 hour 12 hourformat 1to12 24 hourformat 0to23 minutes 00to59 12 00PM Resetremote controller Display s...

Страница 17: ... statusvalue Delaytime UseofERV delaytime ON OFF OFF ERVdelay time 30to60minutes 30 NOTE When two wired remote controllers are connected the brightness can be set within 10 to 50 Current Time Setting Example 1 Press the button 2 Press the or button to select Option and then press the button 3 Press the or button to select User mode and then press the button 4 Press the or button to select Wired re...

Страница 18: ...18 English Setting Options Memo SOL 신규 유선리모컨 LCD 유럽향 IB_EN_DB68 08384A 00_Book_ indd 18 2019 05 16 오후 2 29 19 ...

Страница 19: ...19 English Setting Options SOL 신규 유선리모컨 LCD 유럽향 IB_EN_DB68 08384A 00_Book_ indd 19 2019 05 16 오후 2 29 19 ...

Страница 20: ...SOL 신규 유선리모컨 LCD 유럽향 IB_EN_DB68 08384A 00_Book_ indd 20 2019 05 16 오후 2 29 19 ...

Отзывы: