background image

Air Conditioner

Installation manual

Wired remote controller MWR-WE11N

 

ŷ

Thank you for purchasing this Samsung Product.

 

ŷ

Before operating this unit, please read this installation manual carefully and retain it for future refer-
ence.

DB68-06359A-02

Содержание MWR-WE11N

Страница 1: ...llation manual Wired remote controller MWR WE11N ŷ Thank you for purchasing this Samsung Product ŷ Before operating this unit please read this installation manual carefully and retain it for future refer ence DB68 06359A 02 ...

Страница 2: ...ht X If the place cannot support its weight the product may fall down and it may cause product damage Do not move or reinstall the product on your discretion X Potential risk of electric shock or fire Check if the installation work is done correctly according to the installation manual X Incorrect installation may cause electric shock or fire When you want to dispose your Wired Remote Controller a...

Страница 3: ...ts X Potential risk of electric shock or product damage Do not install the product in areas exposed to oil or vapor X Potential risk of product damage or malfunction Do not put undue stress on the power cable X Potential risk of broken cable and fire Do not install the product in areas with frequent use of acid or alkali spray X Potential risk of electric shock or product malfunction Do not connec...

Страница 4: ...GPSF JOTUBMMJOH ZPVS 8JSFE 3FNPUF POUSPMMFS t OTUBMM UIF 8JSFE 3FNPUF POUSPMMFS DBCMFT JO BDDPSEBODF XJUI UIF FMFDUSJDBM XJSJOH SVMFT BOE BMMPX JU UP QBTT through the inner area of the wall so that other people can t reach it 120 0 4 72 124 0 4 88 63 8 2 51 19 5 0 76 Unit mm inch Wired Remote Controller 1 CableTie 2 Cable Clamp 3 M4X16 Screw 5 User Manual 1 Installation Manual 1 UTerminal 6 ...

Страница 5: ...separate it from the rear cover 2 Arrange the power cable and the communication cable so that they fit in the housing along the edges of the rear cover t OTFSU B øBU IFBE TDSFXESJWFS JOUP UIF TRVBSF HSPPWF JO UIF VQQFS BSFB PG UIF hook to disassemble it easily When the cable is not concealed When the cable is concealed 15 cm 6 inch 10cm 4inch If you need more space for the wiring work you can take...

Страница 6: ...OH BSF UIF TQFDT PG UIF DPNQSFTTJPO SJOH UFSNJOBM DPOOFDUFE UP ZPVS 8JSFE 3FNPUF POUSPMMFS 1 W t G E F L Stud D RangeofPermittedWires Rated Size Stud Size BasicSize mm inch AWG mm2 inch2 mm2 inch2 mm inch t øD G E F W L 22 16 0 25 1 65 0 0003 0 0025 1 5 0 0023 3 0 1181 0 7 0 0275 3 8 0 1496 10 0 0 3937 4 5 0 1771 6 5 0 2559 6 0 0 2362 21 2 0 8346 K Maximum distance for connecting communication and...

Страница 7: ...e for more than five seconds X The system will reset and tracking will start again 3 During tracking the total number of currently searched indoor units and ventilator ERV will be displayed 4 It may take about 5 minutes at initial installation or when you re set the Master setting t G ZPV XBOU UP QFSGPSN USBDLJOH BHBJO BGUFS JOTUBMMBUJPO UIFO QSFTT UIF Delete and ESC buttons at the same time GPS N...

Страница 8: ...NPUF DPOUSPMMFS UP DPOUSPM POF JOEPPS VOJU PS WFOUJMBUPS 37 Wired Remote Controller Installation When Connected to an Indoor Unit Only When Connected to an ventilator ERV Only Outdoor Unit IndoorUnit COM1 F1 F2 COM2 F3 F4 COM1 F1 F2 COM2 F3 F4 COM2 F3 F4 Wired Remote Controller Wired Remote Controller Wired Remote Controller IndoorUnit IndoorUnit t 3FHBSEMFTT PG UIF JOEPPS HSPVQ BEESFTT 3 BEESFTT ...

Страница 9: ... or more indoor units and WFOUJMBUPS 37 BU UIF TBNF UJNF When Connected to an Indoor Unit Only t 3FHBSEMFTT PG UIF JOEPPS VOJU T HSPVQ BEESFTT 3 BEESFTT POMZ UIF JOEPPS VOJUT DPOOFDUFE UP 0 BSF controlled in group t 3FHBSEMFTT PG ZPVS PVUEPPS VOJUT ZPV DBO DPOUSPM B NBYJNVN PG JOEPPS VOJUT BT B HSPVQ t EESFTT PG FBDI PVUEPPS VOJUT NVTU CF TFU EJòFSFOUMZ XIFO HSPVQ DPOUSPM JOEPPS VOJUT DPOOFDUFE UP...

Страница 10: ...OUSPMMFS UP POUSPM 5ISFF WFOUJMBUPS 37 Wired Remote Controller COM2 F3 F4 BTUFS WFOUJMBUPS 37 COM1 F1 F2 Ventilator ERV Ventilator ERV Ventilator ERV COM1 F1 F2 COM2 F3 F4 COM1 F1 F2 t 3FHBSEMFTT PG UIF WFOUJMBUPS 37 hT group address RMC address only the WFOUJMBUPS 37 connected to COM2 controlled in group ...

Страница 11: ...USPMMJOH JOEPPS VOJUT BOE WFOUJMBUPS 37 UPHFUIFS JO HSPVQ ZPV DBO DPOUSPM NBYJNVN PG JOEPPS VOJUT BOE WFOUJMBUPS 37 t G ZPV XBOU UP VTF UIF QPXFS TBWJOH GVODUJPO ZPV IBWF UP DPOOFDU 8JSFE 3FNPUF POUSPMMFS UP POMZ POF JOEPPS VOJU BOE POF WFOUJMBUPS 37 6TJOH 0OF 8JSFE 3FNPUF POUSPMMFS UP DPOUSPM NVMUJQMF JOEPPS VOJUT BOE WFOUJMBUPS 37 2 6TJOH 0OF 8JSFE 3FNPUF POUSPMMFS UP DPOUSPM JOEPPS VOJUT DPOOFD...

Страница 12: ...2 Remote controller X 3FNPUF DPOUSPMMFS JT DPOUSPMMJOH POF JOEPPS VOJU WFOUJMBUPS 37 PS POF HSPVQ PG JOEPPS VOJUT BOE WFOUJMBUPS 37 XJUI UXP SFNPUF DPOUSPMMFST When Connected to an Indoor Unit Only When Connected to an ventilator ERV Only t PS UIF TMBWF 8JSFE 3FNPUF POUSPMMFS TFUUJOHT QMFBTF SFGFS UP UIF TFDUJPOT BCPVU UIF BEEJUJPOBM GVODUJPOT PG UIF Wired Remote Controller Refer to page19 BTUFS 4...

Страница 13: ...nected to an Indoor Unit and an ventilator ERV Together t 3FHBSEMFTT PG UIF JOEPPS VOJU HSPVQ BEESFTT 3 BEESFTT POMZ UIF JOEPPS VOJUT DPOOFDUFE UP 0 BSF controlled by 2 remote controller t PS UIF TMBWF 8JSFE 3FNPUF POUSPMMFS TFUUJOHT QMFBTF SFGFS UP UIF TFDUJPOT BCPVU UIF BEEJUJPOBM GVODUJPOT PG UIF Wired Remote Controller Refer to page19 BTUFS 4MBWF ...

Страница 14: ...BOHJOH OVNCFS PG WFOUJMBUPS 37 JOEPPS VOJU PS UIFJS BEESFTT Wired Remote Controller Installation 1 Press the Delete and ESC buttons at the same time for more than five seconds X PVS 8JSFE 3FNPUF POUSPMMFS XJMM CF JOJUJBMJ FE BOE UIF EFWJDF XJMM TFBSDI GPS UIF JOEPPS VOJUT WFOUJMBUPS 37 connected to your Wired Remote Controller again ...

Страница 15: ...t address for the error will be displayed followed by the error code Example Error 101 occurs for Indoor Unit No 200012 Ventilator ERV When an Error Occurs inYour Ventilator ERV Product Group Display B X The product address for the error will be displayed followed by the error code YBNQMF SSPS IBT PDDVSSFE BU WFOUJMBUPS 37 P When an Error Occurs inYour Wired Remote Controller X Only an error code ...

Страница 16: ...GPS ZPVS JOEPPS PVUEPPS VOJUT BOE WFOUJMBUPS 37 SFGFS UP UIF JOTUBMMBUJPO NBOVBM PG FBDI EFWJDF Setting Cancelling the Mode master indoor unit t PEF NBTUFS JOEPPS VOJU TFUUJOH JT TJNQMZ TFMFDUJOH BO JOEPPS VOJU UIBU XJMM CFDPNF TUBOEBSE BNPOH NBOZ JOEPPS VOJUT UP QSFWFOU NJYFE PQFSBUJPO XIJDI POF PS NPSF JOEPPS VOJUT PQFSBUJOH JO EJòFSFOU PQFSBUJPO mode Setting Connect just 1 indoor unit and stop ...

Страница 17: ...ENGLISH 17 AA Main Menu Sub menu 1 2 3 5 4 6 Data bit Additional Functions ofYourWired Remote Controller Wired Remote Controller Installation Service Mode ...

Страница 18: ...ting screen X Using the buttons select a sub menu number and press the button to enter data setting screen X When you enter the setting stage the current setting will be displayed X Refer to the chart for data settings X Using the buttons select the settings Press the CVUUPO UP NPWF UP UIF OFYU TFUUJOH X Press the Set CVUUPO UP TBWF UIF TFUUJOHT BOE FYJU UP UIF TVC NFOV TFUUJOH TDSFFO X Press the ...

Страница 19: ... 1 Use Useofairpurificationmode 3 0 0 Nouse 1 Use Useofexternalcontrol 4 0 0 Nouse 1 Use 5 RoomTemperature compensation Temperaturecontrolreference 1 2 3 0 9 40 C 15 104 F 0 1 C 5FNQFSBUVSF DPNQFOTBUJPO WBMVF 4 5 6 0 9 9 9 9 C 0 1 C 6 Numberofconnectedunits Numberofindoorunits 1 2 0 16 NumberofERVs 3 4 0 16 7 FTJSFE UFNQFSBUVSF JODSFNFOU EFDSFNFOU POMZ 1 0 0 1 C 1 0 5 C 2 0 1 C 8 4FU IFDL 37 OFSHZ...

Страница 20: ...control 1 0 Nouse 1 Use Coolingdischargetemperature 3 4 8 25 C 46 77 F 1 C Heatingdischargetemperature 5 6 18 43 C 64 109 F 1 C 3 FreshDuctdischarge temperaturechecking Coolingdischargetemperature 1 2 13 25 C 55 4 77 F 1 C Heatingdischargetemperature 3 4 18 30 C 64 86 F 1 C 6 1 37 1MVT TFUUJOH DIFDLJOH 6TF PG DPME BJS QSFWFOUJPO 1 0 Nouse 1 Use Useofhumidificationwhen Heatingthermooff 2 0 Nouse 1 ...

Страница 21: ...it Factory setting Description Unit 8 1 4UBUVT PG VUPNBUJD JS 7PMVNF TFUUJOH 1 0 0 OFF DisabledorCancelled 1 Completion 2 3VOOJOH VUPNBUJD JS 7PMVNF 2 VUPNBUJD JS 7PMVNF 0QFSBUJPO 1 0 0 Disable 1 Enable 3 VUPNBUJD JS 7PMVNF 7PMUBHF 4FUUJOH 1 2 1 3steps 2 Default Forthe TQFDJGJD WPMUBHF PG NPEFM pleaserefertotheinstallation manualofeachproduct 0 1 Reset Factorysetting 1 0 0 Nouse 1 Reset 2 PowerMas...

Страница 22: ...JOH WBMVF XJMM CF EJTQMBZFE 4 Press button to select the desired Data1 X 1SFTT CVUUPO UP TFMFDU OP X The wired remote controller option is set from both cooling and heating to cooling only 5 Press Set button to complete the option setting X 4BWF UIF TFUUJOH WBMVF BOE FYJU UP TVC NFOV 6 Press ESC button to exit to normal mode 1 2 3 4 Data bit Data1 PUI DPPMJOH BOE IFBUJOH PG BO JOEPPS VOJU Data2 Us...

Страница 23: ...ENGLISH 23 Memo ...

Страница 24: ......