Chapter 3
Connecting Cables
MT3204 Series Installation Manual v1.0
78
Copyright © 2018, All Rights Reserved.
Cabling Diagram
The figure below depicts the different cabling options of the MMU:
Figure 71.
Cable Diagram
Table 20.
MMU Connection Cable
From
To
Cable
MGB
MMU
1
Ground Cable: 6 AWG × 1C
MMU
Rectifier
2
Power Cable: 10 AWG
× 2C, 8 AWG
× 2C
CDU
3
CPRI Cable: Single Mode (Outdoor Type)
External Alarm Device
4
UDA Cable Assembly
The inlet hole finishing method of external equipment must be done after
consultation with operation company, if the cable is connected to external
equipment, such as optical distribution box.
- Cables: Power cable, CPRI cables, and UDA cable
MGB
4) UDA Cable
External Alarm Device
[MMU Bottom View]
3) CPRI Cable
1) Ground Cable
2) Power Cable
CDU
DC Distributor