Samsung MIM-B12 Скачать руководство пользователя страница 1

SIM_MIM-B12_EN_IM_26745A-04.indd   10

2014-05-09   오후 5:31:43

Содержание MIM-B12

Страница 1: ...SIM_MIM B12_EN_IM_26745A 04 indd 10 2014 05 09 오후 5 31 43 ...

Страница 2: ...Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product This manual is made with 100 recycled paper KO EN ZH DB98 26745A 04 SIM_MIM B12_EN_IM_26745A 04 indd 11 2014 05 09 오후 5 31 43 ...

Страница 3: ...o install the unit correctly in accordance with the installation manual Incorrect installation of the unit could cause electric shock or fire Make sure to use the power source with separate wiring for installation It could cause fire or damaged Do not attempt to move the unit or reinstall it on your own It could cause electric shock or fire Ensure that all electric works should be done by an autho...

Страница 4: ...ecting the wires Install the unit in a place where the temperature is between 0 C and 39 C and not exposed to direct sunlight It could get electric shock or malfunction of the unit Avoid installing the unit in a place where acidity or alkali liquid or distinctive spray is used It could cause electric shock or malfunction of the unit Avoid putting the button of the unit in contact with sharp edged ...

Страница 5: ...tallation Manual 1 The SIM must be installed by a qualified installer Make sure the main power is turned off before installing the SIM The wires must be installed according to the national electrical wiring regulations Caution SIM_MIM B12_EN_IM_26745A 04 indd 4 2014 05 09 오후 5 31 41 ...

Страница 6: ...ype Duct type 4 Way Cassette type Split type SIM Power meter I M DMS S NET 3 Install indoors and inside of the distribution kit Power meter SIM Power meter I M ELB or NFB should be installed indoors and inside the distribution kit which is proper to the electric equipment standard Caution SIM_MIM B12_EN_IM_26745A 04 indd 5 2014 05 09 오후 5 31 41 ...

Страница 7: ...power meters can be connected to one SIM Only selected RS 485 type power meters from the following suppliers can be used with SIM Omni System Korea Micronics LS Industrial Hansuk Tech 4 Connect the C1 C2 communication cable from SIM to the C1 C2 terminal on DMS 5 Reassemble the SIM Note At most 8 power meters of SIM can be connected to one DMS Input Power 110V 220V Input Frequency 50 60Hz Rated Ou...

Страница 8: ...om 0 to 7 The default switch is set as 0 The address of SIM is set according to the switch setting when powered on If the rotary switch is adjusted after the power is supplied the adjusted address is not reflected To set the adjusted address for rotary switch unplug the power cable and plug it again Caution Power cable DC 12V SIM I M communication cable Connect to DMS SIM_MIM B12_EN_IM_26745A 04 i...

Страница 9: ... Serial Input Module Startup Order 7 Segment LED display All on SIM Serial Input Module address ex 00 SIM Serial Input Module program version ex version 12 3 The channel which is tracking is displayed Displayed until tracking is complete The power consumed by each channel is displayed ex 456 7kW The following order is displayed when SIM is powered on SIM_MIM B12_EN_IM_26745A 04 indd 8 2014 05 09 오...

Страница 10: ... on CH5 LED08 Green Flickers when communicating with the power meter on CH6 LED09 Green Flickers when communicating with the power meter on CH7 LED10 Green Flickers when communicating with the power meter on CH8 Buttons Reference Status K1 Next channel only connected channels are shown K2 Previous channel only connected channels are shown K3 Reset K4 Not used K5 Not used K6 Not used K1 K3 K5 LED01...