 operating

 

_19

EN

G

LIS

H

ADJUSTING THE AIR FLOW DIRECTION

Air flow can be directed to your desired position.

Vertical air flow

Air flow blades move up and down. 
 

1. 

Press the 

Air swing 

 button on the remote control.

 

Air swing indicator will be on and air flow blades move up and down continuously to circulate 
the air.

 

Press the 

Air swing 

 button on the remote control again, to keep the air flow direction in a 

constant position.

Horizontal air flow

Make sure one of the blade pin lever that stick out of the air flow blades are not broken. 
 

1. 

Move the blade pin lever left or right to keep the air flow direction in a constant position you 
prefer.

Be extremely careful with your fingers while adjusting the Horizontal air flow direction. 
There is a potential risk of personal injury when the unit is mishandled.

CAUTION

Blade pin lever

FJM Vivaldi_IB_E_31202A_10.27.09.indd   19

2009-10-27   16:35:58

Содержание MH026FAEA

Страница 1: ...em is 3 times more efficient compare to the other electrical heating appliance so you can further reduce its running cost Now meet year round needs with one air conditioner Look for Everywhere The ele...

Страница 2: ...t www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsafe practices that may result in...

Страница 3: ...power cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner Potential risk of electric shoc...

Страница 4: ...ble concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn th...

Страница 5: ...shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner Potential risk of electric shoc...

Страница 6: ...material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical was...

Страница 7: ...intenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indi...

Страница 8: ...on 19 Vertical air flow 19 Horizontal air flow This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Electromagnetic Compatibility Directive 2004 108 E...

Страница 9: ...he indoor unit to make sure it is not damaged Main parts Display Your air conditioner may slightly look different from illustration shown above depending on your model Air flow blade left and right Ai...

Страница 10: ...k the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power button The room temperature sensor measures indoor room temperature Make sure room te...

Страница 11: ...gh Smart Saver Less energy usage makes your space cool between the temperature range of 24 C 30 C On Timer Set the On Timer on Off Timer Set the Off Timer on Set the function on off Air swing Activate...

Страница 12: ...batteries Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packag...

Страница 13: ...nsor 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear...

Страница 14: ...d temperature You can set the desired temperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to s...

Страница 15: ...e and Auto fan speed indicator appear on the remote control display In Dry mode temperature will be set automatically and will appear on the remote control display Each time you press the Mode button...

Страница 16: ...justs the temperature according to the current room temperature Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan or but...

Страница 17: ...mperature between the range of 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room tempera...

Страница 18: ...he remote control again to keep the air flow direction in a constant position Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken 1 Move the b...

Страница 19: ...last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operating mode changes to...

Страница 20: ...our s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays on If On timer...

Страница 21: ...you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indicator stops blinking and stays on If Off timer is...

Страница 22: ...is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 hours and then turn off automati...

Страница 23: ...ing You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 4 Press the Set Cancel button on the remote control to active it on The...

Страница 24: ...axes your body and raises your temperature slightly Wake up from mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh Set Off timer in mode over 5 hours You feel...

Страница 25: ...d manually see page 19 for instructions If you press the Mode button while the Smart Saver function is on it will cancel the function To deactivate the Smart Saver function 1 Press the Smart Saver but...

Страница 26: ...rned on the Evaporator clean function runs after stopping the air conditioner operation When the air conditioner is turned off The Evaporator clean indicator on the indoor unit display appears and the...

Страница 27: ...ntenance book has to be available for each unit installed CLEANING THE EXTERIOR 1 Wipe the surface of the unit with a slightly wet or dry cloth when needed Do not use Benzene Thinner or CloroxTM They...

Страница 28: ...e panel to open Then slightly push the panel up until the panel is hanged over the hooks of the unit 2 Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Clean the...

Страница 29: ...unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Bio filter sky blue out to remove it from the slot Bio filter can be plac...

Страница 30: ...panel is hanged over the hooks of the unit 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Deodorizing filter black out to re...

Страница 31: ...ghly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on...

Страница 32: ...tion of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect compressor The air conditioner does not start operating immediate...

Страница 33: ...does not set Check if you press the Set Cancel button on the remote control after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area o...

Страница 34: ...drops on the floor HEATING 27 C or less 15 C to 24 C Internal protection triggers and the air conditioner will stop DRYING 18 C to 32 C 5 C to 43 C Condensation may occur on the indoor unit with risk...

Страница 35: ...o POLAND 0 801 1SAMSUNG 172678 022 607 93 33 www samsung com pl PORTUGAL 80820 SAMSUNG 726 7864 www samsung com pt SLOVAKIA 0800 SAMSUNG 726 7864 www samsung com sk SPAIN 902 1 SAMSUNG 902 172 678 www...

Страница 36: ...you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register MH020FA MH026FA MH035FA MH052FA DB98 31202A 1 I F S E P G D FJ...

Отзывы: