1. Product Information: Screen Configuration
13
◇
Note: Zone configuration by screen
The number of cabinets forming the FHD Zone varies depending on the Pitch, and the quantity and location of the
Y8,Signal B'd are also different.
※
Zone is the basic control unit of System
※
The location of the Redundancy Signal Board is installed in the cabinet where the data ends.
[ XPR060-S/XPR060-E ]
. Cabinet Configuration : 12 x 6
. Resolution : 1920 x 960
. # of Y8 : 12 (24 for redundancy)
. # of Signal : 2
[ XPR080-S/XPR080-E ]
. Cabinet Configuration : 15 x 8
. Resolution : 1800 x 960
. # of Y8 : 10 (20 for redundancy)
. # of Signal : 2
[ XPR100-S/XPR100-E ]
. Cabinet Configuration : 20 x 11
. Resolution : 1920 x 1056
. # of Y8 : 15 (30 for redundancy)
. # of Signal : 2