Configuring the Switch
3-206
3
Web
– Click VLAN, 802.1Q VLAN, 802.1Q Tunnel Configuration or Tunnel Trunk
Configuration. Set the mode for a tunnel access port to 802.1Q Tunnel and a tunnel
uplink port to 802.1Q Tunnel Uplink. Click Apply.
Figure 3-114 Tunnel Port Configuration
CLI
– This example sets port 2 to tunnel access mode, and sets port 3 to tunnel
uplink mode.
Traffic Segmentation
If tighter security is required for passing traffic from different clients through downlink
ports on the local network and over uplink ports to the service provider, port-based
traffic segmentation can be used to isolate traffic for individual client sessions.
Traffic belonging to each client is isolated to the allocated downlink ports. But the
switch can be configured to either isolate traffic passing across a client’s allocated
uplink ports from the uplink ports assigned to other clients, or to forward traffic
through the uplink ports used by other clients, allowing different clients to share
access to their uplink ports where security is less likely to be compromised.
Note:
Due to switch ASIC limitations, traffic segmentation is not supported on the
iES4024GP.
Console(config)#interface ethernet 1/2
Console(config-if)#switchport dot1q-tunnel mode access
Console(config-if)#interface ethernet 1/3
Console(config-if)#switchport dot1q-tunnel mode uplink
Console(config-if)#end
Console#show dot1q-tunnel
Current double-tagged status of the system is Enabled
The dot1q-tunnel mode of the set interface 1/1 is Normal mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/2 is Access mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/3 is Uplink mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/4 is Normal mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/5 is Normal mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/6 is Normal mode, TPID is 0x9100.
The dot1q-tunnel mode of the set interface 1/7 is Normal mode, TPID is 0x9100.
.
.
.
Содержание iES4028F
Страница 1: ...iES4028F 4028FP 4024GP ...
Страница 2: ...iES4028F iES4028FP iES4024GP E082008 ST R03 149100041800A 149100040200A 149100041700A 149100000020A ...
Страница 4: ...iv This page is intentionally left blank ...
Страница 10: ...x This page is intentionally left blank ...
Страница 28: ...Contents xxviii This page is intentionally left blank ...
Страница 32: ...Tables xxxii This page is intentionally left blank ...
Страница 46: ...Introduction 1 10 1 This page is intentionally left blank ...
Страница 336: ...Configuring the Switch 3 280 3 This page is intentionally left blank ...
Страница 688: ...Command Line Interface 4 352 4 This page is intentionally left blank ...
Страница 702: ...Glossary Glossary 8 This page is intentionally left blank ...
Страница 710: ...Index 8 Index This page is intentionally left blank ...
Страница 711: ...This page is intentionally left blank ...
Страница 712: ...iES4028F 4028FP 4024GP ...