Configuring the Switch
3-204
3
5. Configure the QinQ tunnel access port to join the SPVLAN as an untagged
member (see “Adding Static Members to VLANs (VLAN Index)” on page 3-195).
6. Configure the SPVLAN ID as the native VID on the QinQ tunnel access port (see
“Configuring VLAN Behavior for Interfaces” on page 3-198).
7. Configure the QinQ tunnel uplink port to 802.1Q Tunnel Uplink mode (see
“Adding an Interface to a QinQ Tunnel” on page 3-205).
8. Configure the QinQ tunnel uplink port to join the SPVLAN as a tagged member
(see “Adding Static Members to VLANs (VLAN Index)” on page 3-195).
Enabling QinQ Tunneling on the Switch
The switch can be configured to operate in normal VLAN mode or IEEE 802.1Q
(QinQ) tunneling mode which is used for passing Layer 2 traffic across a service
provider’s metropolitan area network. You can also globally set the Tag Protocol
Identifier (TPID) value of the tunnel port if the attached client is using a nonstandard
2-byte ethertype to identify 802.1Q tagged frames.
Command Usage
• Use the TPID field to set a custom 802.1Q ethertype value on the selected
interface. This feature allows the switch to interoperate with third-party switches
that do not use the standard 0x8100 ethertype to identify 802.1Q-tagged frames.
For example, if 0x1234 is set as the custom 802.1Q ethertype on a trunk port,
incoming frames containing that ethertype are assigned to the VLAN contained in
the tag following the ethertype field, as they would be with a standard 802.1Q trunk.
Frames arriving on the port containing any other ethertype are looked upon as
untagged frames, and assigned to the native VLAN of that port.
• All ports on the switch will be set to the same ethertype.
Command Attributes
•
802.1Q Tunnel
Status
– Sets the switch to QinQ mode, and allows the QinQ
tunnel port to be configured. The default is for the switch to function in normal
mode.
•
802.1Q Ethernet Type
– The Tag Protocol Identifier (TPID) specifies the ethertype
of incoming packets on a tunnel port. (Range: hexadecimal 0800-FFFF;
Default: 8100)
Web
– Click VLAN, 802.1Q VLAN, 802.1Q Tunnel Configuration. Check the Enabled
box, set the TPID of the ports if the client is using a non-standard ethertype to
identify 802.1Q tagged frames, and click Apply.
Figure 3-113 802.1Q Tunnel Status and Ethernet Type
Содержание iES4024GP
Страница 1: ...iES4028F 4028FP 4024GP ...
Страница 2: ...iES4028F iES4028FP iES4024GP E082008 ST R03 149100041800A 149100040200A 149100041700A 149100000020A ...
Страница 4: ...iv This page is intentionally left blank ...
Страница 10: ...x This page is intentionally left blank ...
Страница 28: ...Contents xxviii This page is intentionally left blank ...
Страница 32: ...Tables xxxii This page is intentionally left blank ...
Страница 46: ...Introduction 1 10 1 This page is intentionally left blank ...
Страница 336: ...Configuring the Switch 3 280 3 This page is intentionally left blank ...
Страница 688: ...Command Line Interface 4 352 4 This page is intentionally left blank ...
Страница 702: ...Glossary Glossary 8 This page is intentionally left blank ...
Страница 710: ...Index 8 Index This page is intentionally left blank ...
Страница 711: ...This page is intentionally left blank ...
Страница 712: ...iES4028F 4028FP 4024GP ...