44
Warning
Ensure that the rack has anti-tip measures in place. Such measures may include floor-bolting and anti-tip
feet specified by the rack manufacturer and applicable codes.
Warning
To reduce the risk of personal injury or damage to the equipment, at least two people are required to
lift the ES NAS during installation or removal.
Mounting the Device
Position left and right rack rails at the desired 'U' position in the rack (step 1 in Figure 1).
Important
When installing the rack rails, be sure they are oriented Front Left and Front Right, as indicated on
the rails.
Note
: The rails can be adjusted to fit the rack.
Push the release tab to hang the hooks of the rails onto the rack holes and release the tab to
snap the rails into place. Secure the back end of the rails to the back rack columns by using the
screws provided (Step 2 in Figure 1).
Figure 1: Attach the rails to the rack columns
1U