3. Unit combination
Installer reference guide / Mono tank integrated type
21
3.2 Unit combination
Indoor unit / Outdoor unit compatibility
Indoor unit
Tank integrated hydro unit (Mono)
200L(1Φ)
260L(1Φ)
260L(3Φ)
Type
Power
Source
Model name
Capa.
AE200RNWMEG/EU AE260RNWMEG/EU AE260RNWMGG/EU
Outdoor
unit
Mono
HT
Quiet
1Φ
AE080BXYDEG
8kW
●
●
AE120BXYDEG
12kW
●
●
AE140BXYDEG
14kW
●
●
3Φ
AE080BXYDGG
8kW
●
AE120BXYDGG
12kW
●
AE140BXYDGG
14kW
●
Mono
1Φ
AE050RXYDEG
5kW
●
AE080RXYDEG
8kW
●
●
AE120BXYDEG
12kW
●
●
AE160RXYDEG
16kW
●
●
3Φ
AE080RXYDGG
8kW
●
AE120RXYDGG
12kW
●
AE160RXYDGG
16kW
●
3.3 Controller compatibility
Name
Model
Tank integrated hydro unit
&
R32 Outdoor unit
Integrated Management System
DMS 2.5
MIM-D01AN
●
Centralized Control System
Touch Centralized Controller
MCM-A300N
●
Wi-Fi Kit
MIM-H04N
●
Interface Module & Gateway
PIM
(Pulse Interface Module)
MIM-B16N
●
Modbus Interface Module
MIM-B19N
●
Individual Control System
EHS Wired Remote Controller
MWR-WW10N
●
Installation/ Test run solution
S-Converter
MIM-C02N
●
Others
External Room Sensor
MRW-TA
●