Installation requirements
English
11
Ducting requirements
Recommended
Use only for short-run installation
Weather hood
type
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Metallic
flexible*
Rigid
Metallic
flexible*
0
80 ft. (24.4 m)
41 ft. (12.4 m)
74 ft. (22.6 m)
33 ft. (10.1 m)
1
68 ft. (20.7 m)
37 ft. (11.2 m)
62 ft. (18.9 m)
29 ft. (8.8 m)
2
57 ft. (17.4 m)
33 ft. (10.1 m)
51 ft. (15.5 m)
25 ft. (7.6 m)
3
47 ft. (14.3 m)
29 ft. (8.8 m)
41 ft. (12.5 m)
21 ft. (6.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system, make
sure:
• The exhaust system meets all applicable local, state, and national regulations.
• Not to use a flexible plastic duct.
• To regularly check and clean all lint buildup from inside the existing ducts.
• The duct is not kinked or crushed.
• The exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
DV7750M-03170Y-00_EN.indd 11
2016-12-28 11:43:17
Содержание DVEG52M775 SERIES
Страница 1: ...Dryer User manual DVE G 52M775 DV7750M 03170Y 00_EN indd 1 2016 12 28 11 43 16 ...
Страница 57: ...Sèche linge Manuel d utilisation DVE G 52M775 DV7750M 03170Y 00_CFR indd 1 2016 12 28 11 49 28 ...
Страница 113: ...Secadora Manual del usuario DVE G 52M775 DV7750M 03170Y 00_MES indd 1 2016 12 28 11 51 14 ...