Installation requirements
English
18
Installation requirements
Ducting requirements
Weather hood type
Recommended
Use only for short-run
installation
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90° elbows
Rigid
Rigid
0
80 ft. (24.4 m)
74 ft. (22.6 m)
1
68 ft. (20.7 m)
62 ft. (18.9 m)
2
57 ft. (17.4 m)
51 ft. (15.5 m)
3
47 ft. (14.3 m)
41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column
or be less than 0. Note that these values are measured with the dryer running with a
manometer presented to the exhaust duct that connects to the dryer. The dryer tumbler
must be empty and lint filter clean.
Untitled-21 18
2020-07-14 3:47:37
Содержание DVE50R8500 Series
Страница 1: ...Dryer User manual DVE G 50R8500 Untitled 21 1 2020 07 14 3 47 34 ...
Страница 70: ...Memo Untitled 21 70 2020 07 14 3 47 50 ...
Страница 71: ...Memo Untitled 21 71 2020 07 14 3 47 50 ...
Страница 73: ...Sèche linge Manuel d utilisation DVE G 50R8500 Untitled 22 1 2020 07 14 3 49 45 ...
Страница 142: ...Mémo Untitled 22 70 2020 07 14 3 50 00 ...
Страница 143: ...Mémo Untitled 22 71 2020 07 14 3 50 00 ...
Страница 145: ...Secadora Manual del usuario DVE G 50R8500 Untitled 20 1 2020 07 14 3 45 36 ...