8
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to dryer before
servicing, unless testing requires power.
COMPONENT TESTING PROCEDURES
Component Electrical Testing (with ohmmeter)
Thermistor resistance 10K Ω @ 25°C 77°F
Thermostat 1 resistance < 1Ω
Thermostat 3 resistance < 1Ω
- If resistance is infinity, replace thermostat 3.
Thermostat 2 resistance < 1Ω
- If resistance is infinity, replace thermostat 2.
Heater resistance 13 Ω (PIN 2-3)
Heater resistance 34 Ω (PIN 1-2)
- If resistance is infinity, replace Heater.
Measure resistance of the following terminal
1)
Door switch : Off
Terminal : “COM” - “NC” (1-3) : <1Ω
Terminal : “COM” - “NO” (1-2) : ∞ Ω
2)
Door switch : On
Terminal : “COM” - “NC” (1-3) : ∞ Ω
Terminal : “COM” - “NO” (1-2) < 1Ω
Belt Cut-off S/W
- Lever open: Resistance value < 1Ω
- Lever push: Resistance value : ∞ Ω
Vent Sensing - Thermistor Resistance
238.23K Ω @ 25
℃
77
℉
Motor (Electronic & GAS)
Contacts
= Contact closed
Centrifugal Switch (Motor)
2.0Ω between
Pin# 3 and 4
2.3Ω between
Pin# 4 and 5
Function
1M
2M
3M
5M
6M
Start
Run
DV9000HA DRY_TECH MANUAL_DC68-03171F_EN.indd 8
2014-1-17 14:00:28