6
No Problem
What To Check or Do
1
Will Not Start or Run
•
Confirm all wires are hooked up to their corresponding
terminals.
•
Confirm dryer is plugged in.
•
Check for blown fuse or circuit breaker.
•
If door switch functional...door closed. Check for error code 3
(See Table for code definition).
•
Check if Start/Pause rotary selector dial functional.
•
Check if Control Board operational.
•
Check if belt off or broken and Belt Cut-off Switch operates.
•
Check if drive motor functional.
•
Check motor winding resistance: 2.88ohms between pin #3 and
4, 3.5ohms between pin #4 and 5.
2
Motor runs/ tumbler
will not turn
•
Check if belt off or broken/damaged.
•
Check if idler tension spring too weak or stretched.
•
Check if idler pulley jammed or stuck.
3
Runs a few minutes
and then stops
•
Check for lint buildup around drive motor.
•
Check if low voltage present.
•
Check if blower impeller blocked in blower housing.
•
Check if drive motor - start switch contacts stuck closed.
4
Blows fuses or trips
circuit breaker
-
Is the belt connected well?
-
Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)
-
Is the motor protector normal?
•
If there are no problems with the items above, the PCB assembly
is defective. Replace it.
5
Blows fuses or trips
circuit breaker (Gas
Model)
•
During ignition, the dryer will draw X amps. With the burner ON,
the dryer will draw X amps. If the dryer is drawing amperages
above this, then suspect the house wiring, fuse box, or circuit
breaker is at fault.
•
Igniter harness loose and shorted to base.
•
Incorrect wiring or wire shorted to ground.
•
Drive motor winding shorting to ground.
6
Will not heat (motor
runs)
Open heating element. Check if:
•
Hi-Limit trips easily or is open.
•
Regulating thermostat trips easily or is open.
•
Membrane switch open.
•
Check Thermistor.
7
Will Not Dry Gas
Model Poor Gas
Ignition
When the dryer is operated on a heat setting, the igniter should be
energized and burner should fire within 45 seconds at 120 VAC. The
failure of a component in this system will usually be indicated by one
of three symptoms:
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to dryer before
servicing, unless testing requires power.