Installation requirements
English
15
Exhausting requirements
The dryer must not be exhausted into a
chimney, a wall, a ceiling, an attic, a crawl
space, or a concealed space of a building.
Exhausting the dryer to the outside will
prevent large amounts of lint and moisture
from being blown into the room.
In the United States and Canada
• All dryers must be exhausted to the
outside.
• The required exhaust duct is 4 inches
(10.2 cm) in diameter.
• See “
” section for the maximum
duct length and number of bends that
can be used.
• The total length of flexible metal duct
must not exceed 7’ 10½” (2.4 m).
• Do not assemble the duct with screws
or other fasteners that extend into the
duct and catch lint.
•
For the United States only:
Use only
those foil-type flexible ducts, if any,
specifically identified for use with the
appliance by the manufacturer and that
comply with the Outline for Clothes
Dryer Transition Duct. Use Subject
2158A.
Outside the United States and Canada
• Refer to the local codes.
WARNING
• You must exhaust the dryer to the
outside to reduce the risk of fire when
you install the dryer in an alcove or
closet.
• Do not use a plastic or non-metal
flexible duct.
• If your existing ductwork is plastic, non-
metal, or combustible, replace it with
metal.
• Use only a metal exhaust duct that is
non-flammable to ensure containment
of exhaust air, heat, and lint.
DV7500K_DC68-03381C-07_EN.indd 15
2018-10-22 3:21:26
Содержание DV45K6200E Series
Страница 74: ...Memo DV7500K_DC68 03381C 07_EN indd 74 2018 10 22 3 22 11 ...
Страница 75: ...Memo DV7500K_DC68 03381C 07_EN indd 75 2018 10 22 3 22 11 ...
Страница 150: ...Mémo DV7500K_DC68 03381C 07_CFR indd 74 2018 10 22 4 54 14 ...
Страница 151: ...Mémo DV7500K_DC68 03381C 07_CFR indd 75 2018 10 22 4 54 14 ...
Страница 227: ...Notas DV7500K_DC68 03381C 07_MES indd 75 2018 10 22 4 38 15 ...