background image

1

CLOTHES DRYER

Technical Information

CAUTION

All safety information must be followed as provided in Service Manual of DV431, DV231.

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer 
before servicing, unless testing requires power.

Code No. : DC68-02365D-02

IMPORTANT SAFETY NOTICE – “For Technicians only” This service data sheet is intended for 
use by persons having electrical, electronic, and mechanical experience and knowledge at a level 
generally considered acceptable in the appliance repair trade. Any attempt to repair a major 
appliance may result in personal injury and property damage. The manufacturer or seller cannot 
be responsible, nor assume any liability for injury or damage of any kind arising from the use of 
this data sheet.

• 

Due to possibility of personal injury or property damage, always contact an authorized 

technician for servicing or repair of this unit.

• 

Refer to Service Manual (

DV431, DV231) for detailed installation, operating, testing, 

troubleshooting, and disassembly instructions.

(Technical)DV431AEP-02365D-02.indd   1

2011-07-08   �� 5:35:57

Содержание DV431

Страница 1: ...ctronic and mechanical experience and knowledge at a level generally considered acceptable in the appliance repair trade Any attempt to repair a major appliance may result in personal injury and property damage The manufacturer or seller cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this data sheet Due to possibility of personal injury or p...

Страница 2: ...dF Invalid door state for more than 256 milliseconds Check for Loose or open wire terminals in Door Sense circuit bE2 Invalid state of key circuit short for 30 secs Check for Display PCB key circuit short or not FE Invalid power source Frequency Check for Not using regular power source frequency Invalid power frequency sense circuit 2E Electronic Control Problem Over Voltage Error Check for Check ...

Страница 3: ...vice mode How to enter With Power On pressing Mixed Load Bell Temp DV431 or Wrinkle Prevent Temp DV231 for 3 seconds This action will put the dryer into sensor bar touch data mode Dryer will display Sensor Bar data Cycle Count Mode Definition of Sensor Bar Touch Data Mode This mode is to bring up the total number of cycles that User have carried out How to enter Press the Mixed Load Bell DV431 orT...

Страница 4: ...AdjsutDown Key for 7 seconds until it sends out a beeping sound If not pressed any keys for 5 minutes it will be set back from Data Display Mode If pressing AdjustUp Key in this mode Display Mode ID will be incresed If pressing AdjustDown Key in this mode Display Mode ID will be decresed Definition of Software Version Mode Display Mode 0 Temperature data Display Mode 1 Average Touch Sensor data fo...

Страница 5: ...arth or remove the potential differ ence of the human body and dryer by contacting the power supply plug when the work contacting to PCB is executed 2 As the P C B assembly is designed for no trouble do not replace the P C B assembly by the wrong diagnosis and follow the procedure of the trouble diagnosis when the micom is not operated normally ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of el...

Страница 6: ...ing stator winding generator Is the motor protector normal If above points are not found the PCB assembly is out of order Replace it 5 Blows fuses or trips circuit breaker Gas Model During ignition the dryer will draw X amps With the burner ON the dryer will draw X amps If the dryer is drawing amperages above this then the house wiring fuse box or circuit breaker is suspected to be at fault Ignite...

Страница 7: ... filter is not clean Restriction in exhaust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower impeller bound check for foreign material in blower area Customer overloading dryer Check clothing labels for fabric content and cycle selected Clothes too wet ...

Страница 8: ... replace thermostat 2 Heater resistance 10 Ω If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch open Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch push On Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Lamp resistance 80 100 Ω Violet gray Motor Electronic GAS Co...

Страница 9: ... value 1 Ω If resistance is infinite replace Radiant sensor Igniter 101D Resistance value 40 400 Ω If resistance is infinite replace Igniter Gas Valve 25M01A Valve 1 2 Resistance value 1 2K Ω Valve 1 3 Resistance value 0 5K Ω Valve 4 5 Resistance value 1 2K Ω If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 Ω If resistance is infinity replace Thermostat...

Страница 10: ...servicing unless testing requires power Sensor Bars temperature sensor check Sensor Bars Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx Ω without laundry Approx 190Ω 10 with wet clothes Cycling Thermistor Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6 Approx 10 KΩ at 25 C 77 F RY7 ...

Страница 11: ...pper wire of power cord C 1 9 cm UL listed strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire 1 Remove the External ground connector screw 2 Connect the ground wire green or unwrapped of the power cord to the external ground connector screw If you want to connect B Green or bare copper wire of power cord to the Neutr...

Страница 12: ...RAM WIRING DIAGRAM WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power OPTION 1 Steam Models Only OPTION 3 DR READY Models Only ...