Testing Main PCB power 

output to Heating 

& Motor circuit. 

With motor running in the heating mode, 
read AC voltage across RY6 and RY5. 

Any voltage reading means Main PCB is  
defective. 

See page 4 for Main PCB layout for testing.

 

Testing Motor circuit. 

With power off read 
resistance between 
RY5 Brown and CN7 
Blue. 

Resistance reading of 
good motor circuit is 
about 1.9

. To test 

thermostat and switch 
use ohm meter on      
lowest scale, any            
resistance replace 
component. 

See page 4 for Main 
PCB layout for testing.

 

Содержание DV210AEW

Страница 1: ...ce Dryer Thermistor Open Sensed The Thermistor resistance is very high Check for Clogged lint screen Restricted vent system Thermistor resistance dO dE Door Open Running the dryer with door open Check for Loose or open wire terminals in Door Sense circuit FE Power source frequency Error Invalid power source Frequency Check for Non Utility power supply dF Door Circuit Failure Invalid state for more...

Страница 2: ...CN4 RY 6 CN6 RY 5 CN7 CN5 CN1 ...

Страница 3: ...CN4 RY 6 CN6 RY 5 CN7 CN5 CN1 ...

Страница 4: ...c L1 Blk Relay 6 1 Heater Cut Off T Stat Blu 2 120vac L1 Blk CN5 1 Lamp Vio CN6 1 Earth Ground Grn CN4 3 6 Thermistor Blu Red 4 5 Moisture Sensor Pnk Org CN2 Sub PCB Display 5 4 5VDC Wht Pnk 6 4 15VDC Red Pnk CN7 1 Motor 6 Blk 2 Door Sw Blu Thermistor W0035 DC32 00007A F0005 DC47 00016A New Version of Blower Housing it may be necessary to separate the harness wrap on replacement housing Please mai...

Страница 5: ...l illuminate when Wrinkle Prevent is selected Chasing lights appear in the display when the Wrinkle Prevent option is selected The load is dry and can be removed at any time during the Wrinkle Prevent cycle SUBJECT Dryer belt slides off the pulley when manually rotated counter clockwise ccw SYMPTOM The dryer drum will not turn On occa sions the customer will rotate the drum counter clockwise CCW t...

Страница 6: ...r on start dryer read voltage between RY6 Blue wire and CN6 Green wire Reading of 120VAC means a proper operating heater circuit 0VAC means open in circuit To test thermostats use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...

Страница 7: ...age reading means Main PCB is defective See page 4 for Main PCB layout for testing Testing Motor circuit With power off read resistance between RY5 Brown and CN7 Blue Resistance reading of good motor circuit is about 1 9Ω To test thermostat and switch use ohm meter on lowest scale any resistance replace component See page 4 for Main PCB layout for testing ...

Отзывы: