background image

Fast Track Troubleshooting 

Publication #  tsDV203   Creation Date 1/22/2010

 

IMPORTANT SAFETY NOTICE

 – 

“For Technicians Only”

  This service data sheet is 

intended for use by persons having electrical, electronic, and mechanical experience 
and knowledge at a level generally considered acceptable in the appliance repair trade.  
Any attempt to repair a major appliance may result in personal injury and property 
damage.  The manufacturer or seller cannot be responsible, nor assume any liability for 
injury or damage of any kind arising from the use of this data sheet. 

Models:    DV203*** 
DV206***  DV209*** 
DV218***  DV219*** 
DV306***  DV316***  
DV317***  DV326***  
DV328***  DV337***  
DV338***  DV3C6*** 

 

Description 

Trigger 

Action Taken

Dryer Thermistor Short 
Sensed

The Thermistor resistance is 
very low.

Check for: Clogged lint screen,  
Restricted vent system, Thermistor 
resistance.

Dryer Thermistor Open 
Sensed

The Thermistor resistance is 
very high.

Check for: Clogged lint screen,  
Restricted vent system, Thermistor 
resistance.

do

Door Open

Running the dryer with door 
open

Check for: Loose or open wire 
terminals in Door Sense circuit.

FE

Power source frequency 
Error

Invalid power source Frequency  Check for: Non Utility power supply

dF

Door Circuit Failure

Invalid state for more than 256 
milliseconds

Check for: Loose or open wire 
terminals in Door Sense circuit.

hE or HE

Heater Error

Invalid heating Temp in running 
the dryer

Check for: Restricted vent system, 
Thermistor resistance.

bE

Button Error

PCB key closed for 75 sec.

Check Display PCB for stuck button

Samsung 'Dryer' Diagnostic Code Quick Guide

Display 

Do not use dryer to dry clothes which have traces of any flam-
mable substance, such as vegetable oil, cooking oil, machine 
oil, flammable chemicals, thinner, etc., or anything containing 
wax or chemicals, such as mops and cleaning cloths. Flamma-
ble substances may cause fabric to catch fire by itself.

 

Location consideration In the USA

• 

All Dryers Must be vented to the outside. 

• 

Only rigid or flexible metal duct should be 
used for venting.

 

Electrical Dryers 240 VAC, 60 Hz, 30 Amps, 3
-wire or 4-wire installations 

Gas Dryers 120 VAC, 60 Hz, 15 Amps, 3-wire 
installations 

TOUCH UP PAINT, BLUE ONYX

DH81-11980A

TOUCH UP PAINT, IMPERIAL SILVER DH81-11981A
TOUCH UP PAINT, NEAT WHITE

DH81-11982A

TOUCH UP PAINT, STRATUS GRAY

DH81-11983A

TOUCH UP PAINT, TANGO RED

DH81-11984A

1