SAMSUNG
MMC PROGRAMS
COMBINED SYSTEMS PROGRAMMING MANUAL
FEBRUARY 2004
MMC 861 (Page 1 of 1)
MMC: 861
SYSTEM OPTIONS
FOR:
OS500
Purpose:
Sets a number of system options
Options are:
AUTO UPDATE TIME
Updates the system time from the ISDN network (Enable /
Disable)
SYSTEM SPEED BIN
Maximum number of system speed dials assigned to system
(500 or 950)
IDLE WHEN ENBLOC
Enable/Disable
2-LINE ENBLOC
Enables Enbloc dialling on 2-Line LCD phones (Enable / Dis-
able)
ACTION
DISPLAY
1. Open programming and select
861
Display shows
AUTO UPDATE TIME
ENABLE
2. Press VOLUME keys to select option (see table
above) and press RIGHT soft key
AUTO UPDATE TIME
ENABLE
3. Press VOLUME keys to select other options as
required
AUTO UPDATE TIME
DISABLE
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
AUTO UPDATE TIME=DISABLE
SYSTEM
SPEED
BIN=500
IDLE
WHEN
ENBLOC=DISABLE
2-LINE
ENBLOC=DISABLE