SAMSUNG
Programming
DCS-816
February, 1999
MMC 204 (Page 1 of 1)
MMC: 204
COMMON BELL CONTROL
DESCRIPTION:
Determines whether the common bell relay contacts have an interrupted or
continuous closure when activated. If interrupted is chosen, the relay follows an
internal C.O. ring pattern of one second closed followed by three seconds open.
If assigned dry contact to Common bell, common bell relay pairs are assigned as
362.
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Used to store data and advance to next MMC
ACTION
DISPLAY
1.
Press TRSF 204
Display shows current setting
[362] COM/LD BEL
CONTINUOUS
2.
Dial common bell number (362 only)
OR
Press UP or DOWN key to make selection of
common bell numbers and press RIGHT soft
key to advance cursor
[362] COM/LD BEL
CONTINUOUS
3.
Dial 0 for continuous or 1 for interrupted
operation
OR
Use UP or DOWN to scroll through options
Press RIGHT soft key to return to step 2
[362] COM/LD BEL
INTERRUPTED
4.
Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: Continuous
(When Common bell or Loud bell is assigned
at MMC 219)
RELATED ITEMS: MMC 203 Assign UA Device
MMC 219 Common Relay Service Type
MMC 601 Assign Station Group
Содержание DCS-816
Страница 1: ...General Description for Europe DCS 816 ...
Страница 2: ...Programming Manual DCS 816 ...
Страница 239: ...Part No GA68 60754A ED 01 Printed in Korea ...
Страница 240: ...Installation Manual for Europe DCS 816 ...
Страница 263: ...SAMSUNG Installation DCS 816 February 1999 4 4 This page is intentionally left blank ...
Страница 285: ...Part No GA68 60751A ED 01 Printed in Korea ...
Страница 286: ...System Administration and Special Features Guide DCS 816 ...
Страница 313: ...Part No GA68 60756A ED 01 Printed in Korea ...