Deciding on where to install the air conditioner
General
When deciding on the location of the air conditioner with the owner, the following restrictions must be taken
into account.
Do NOT install the air conditioner in a location where it will come into contact with the following elements :
◆
Combustible gases
◆
Saline air
◆
Machine oil
◆
Sulphide gas
◆
Special environmental conditions
◆
The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not
suitable to be installed in areas used for laundry. If you must install the unit in such conditions, first consult your dealer.
◆
The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling
circuit and seriously damage the unit.
◆
Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.
◆
Do not block any passageways or thoroughfares.
◆
Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours.
◆
Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended
length will be respected.
◆
Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary
noise and vibration.
◆
Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.
◆
Maintain sufficient clearance around the outdoor unit, as indicated in page 8.
◆
Make sure that the water dripping from the drain hose runs away correctly and safely.
Outdoor Unit
The following accessories are supplied with the air conditioner.
Accessories in the outdoor unit case
※
Attach Energy Label to the outdoor unit properly when installing.
≫
The 3-wire power cable and the 2-wire assembly cable are optional. If these cables are not supplied,
use the standard cable approved by IEC standard.
Please, check “Method for connecting wires” section.
◆
You have just purchased a Free Joint Multi air conditioner and it has been installed by your installation specialist.
◆
This device must be installed according to the national electrical rules.
◆
Max input power & current is measured according to IEC standard and input power & current is measured
according to ISO standard.
◆
More than 2 indoor units should be installed when you use Free Joint Multi air conditioner.
◆
Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either
accessibility from both sides or ability to perform routine maintenance and repairs.
The units’ components must be accessible and that can be disassembled in conditions of complete safety either for
people or things. For this reason, where it is not observed as indicated into the Installation Manual, the cost
necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks,
scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.
◆
With an outdoor unit having net weight upper than 60kg, we suggest do not install it suspended on wall,
but considering floor standing one.