4. Troubleshooting
4.5.7. U1-xxxx type (Fuser) error code
► Error Code
U1–2113
U1–2119
► Error message
Fuser Unit Failure: #U1-2113.
Fuser Unit Failure: #U1-2119.
► Symptom
The thermistor can’t measure temperature. The hear-roller will not heat-up.
► Troubleshooting method
1) Turn the machine off. Re-install the fuser unit, then turn the machine on.
(Refer to 3.2.2 Fuser unit)
2) Remove the fuser unit. After openinging the jam cover, check if jammed or wrapped paper is in the fuser unit.
3) If the problem persists, check the following :
(Refer to 3.3.23. Fuser unit)
a) Check if the Halogen lamp
(110V : 4713-001630 / 220V : 4713–001631)
is broken or disconnected.
b) Check if the AC connection of the Halogen lamp is disconnected or contaminated.
Copyright© 1995-2016 SAMSUNG. All rights reserved.
4-184
Содержание CLX-9251 Series
Страница 122: ...2 Product Specifications and Description 2 108 Copyright 1995 2016 SAMSUNG All rights reserved ...
Страница 167: ...3 Disassembly and Reassembly 7 Remove the Cover Side F Copyright 1995 2016 SAMSUNG All rights reserved 3 45 ...
Страница 454: ...4 Troubleshooting 4 269 Copyright 1995 2016 SAMSUNG All rights reserved ...