4. Troubleshooting
4.5.1. Ax-xxxx type error code
► Error Code
A1–1111
A1–1113
► Error message
Motor Failure: #A1-1111. Turn off then on. Call for service if the problem persists.
Motor Failure: #A1-1113. Turn off then on. Call for service if the problem persists.
► Symptom
Regi/MP motor operation is abnormal.
► Troubleshooting method
•
A1–1111 : Regi/MP motor is stopped but machine recognizes it as operational.
•
A1–1113 : Regi/MP motor is operating but machine recognizes status as "Stopped".
1) Turn the machine off then on. If the error persists, turn the machine off again.
2) Open the side cover. Check if there are any foreign substances or paper around Regi./MP unit.
3) Remove the rear cover after removing 10 screws.
4) Check if the Regi/MP motor connector is connected correctly.
5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test.
(Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0000)
Check the motor operation.
a) If the motor is not operational,
4-63
Copyright© 1995-2016 SAMSUNG. All rights reserved.
Содержание CLX-9251 Series
Страница 122: ...2 Product Specifications and Description 2 108 Copyright 1995 2016 SAMSUNG All rights reserved ...
Страница 167: ...3 Disassembly and Reassembly 7 Remove the Cover Side F Copyright 1995 2016 SAMSUNG All rights reserved 3 45 ...
Страница 454: ...4 Troubleshooting 4 269 Copyright 1995 2016 SAMSUNG All rights reserved ...