Samsung Electronics
7-2
7-2 Basic Structure
7-2-1 Micom Control Diagram
A/D converter
• Air swing motor control
• Compressor control
• Buzzer control
• Temperature control
Reset Circuit
Remocon Single Receiving
FAN SPEED(HIGH,LOW)
TEMP. SETTING(
▼▲
)
TIMER SETTING(
▼▲
)
COOL
FAN
ON/OFF
AIR SWING
Compressor
Fan motor
Power circuit (DC 5V)
Power circuit (DC 12V)
Down Trans (AC13V ~ AC17V)
Power input (AC198V ~ AC264V)
Oscillation Circuit
LED CONTROL
• Mode(COOL, FAN)
• Temperature Display
• Temp
• HR
MICOM
Remote Cotrol
Room Temperature Sensor
Receiving Unit of Remocon
Air swing motor
AW126JB-3 6/27/98 10:42 AM Page 4
Содержание AW127JB
Страница 24: ...Samsung Electronics 6 2 Ass y Control 6 3 1 7 6 5 9 8 13 2 3 4 12 14 10 11...
Страница 30: ...8 1 Samsung Electronics 8 PCB Diagram 8 1 Main PCB ASS Y CODE NO DB93 10502A...
Страница 35: ...10 Schematic Diagrams 10 1 Main PCB Samsung Electronics 10 1 AW126JB 4 6 27 98 11 55 AM Page 1...
Страница 36: ...10 2 Samsung Electronics 10 2 Remote Control...