background image

Содержание AQV09ABAX

Страница 1: ......

Страница 2: ...eat pump system Heat pump system is 3 times more efficient compare to the other electrical heating appliance so you can further reduce its running cost Now meet year round needs with one air condition...

Страница 3: ...help and information online at www samsung com Important safety symbols and precautions WARNING Hazards or unsafe practices that may result in severe personal injury or death CAUTION Hazards or unsaf...

Страница 4: ...damaged or dusted power plug power cable or loosened power receptacle Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner P...

Страница 5: ...measures to prevent the allowable concentration from being exceeded If the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If th...

Страница 6: ...l risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner P...

Страница 7: ...disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner m...

Страница 8: ...there are no obstacles under the indoor unit Potential risk of fire or loss of property Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If pr...

Страница 9: ...7 Fan 18 Heat 19 Adjusting the air flow direction 19 Vertical air flow 19 Horizontal air flow This product has been determined to be in compliance with the Low Voltage Directive 2006 95 EC and the Ele...

Страница 10: ...CHECKING THE INDOOR UNIT AND DIGITAL DISPLAY Carefully unpack your air conditioner and check the unit to make sure it is not damaged Main parts Your air conditioner may look slightly different from th...

Страница 11: ...Power button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pre...

Страница 12: ...nt fan speeds such as Auto Silence Low Medium High On Timer Set the On Timer on Off Timer Set the Off Timer on Set the function on off Air swing Activate Deactivate air flow blade movement automatical...

Страница 13: ...ter Inserting the batteries Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery...

Страница 14: ...r conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote contro...

Страница 15: ...f 16 C 30 C You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room temperature reaches desired value th...

Страница 16: ...emote control until Dry mode and Auto fan speed indicator appear on the remote control display Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat While you...

Страница 17: ...according to the current room temperature Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan or button on the remote con...

Страница 18: ...e temperature by 1 C 4 Set the fan speed Press the Fan or button on the remote control to set the desired fan speed If room temperature reaches desired value heating will stop for a while Each time yo...

Страница 19: ...he air Press the Air swing button on the remote control again to keep the air flow direction in a constant position Horizontal air flow Make sure one of the blade pin lever that stick out of the air f...

Страница 20: ...0 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan...

Страница 21: ...control display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops bl...

Страница 22: ...display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indicator stops blinking...

Страница 23: ...e preset time of the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 ho...

Страница 24: ...mote control to change the time setting while Off timer indicator is blinking You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hour...

Страница 25: ...he temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh Set Off timer...

Страница 26: ...e energy while the air conditioner is operating in Cool mode 1 Press the Energy saving button on the remote control while the air conditioner is operating in Cool mode E Saver indicator and air swing...

Страница 27: ...When the air conditioner is turned on the Evaporator clean function runs after stopping the air conditioner operation When the air conditioner is turned off The Evaporator clean indicator on the indoo...

Страница 28: ...remote control display The air conditioner will operate more quietly Silence function is only available in Cool Heat mode When the Silence function is activated pressing Mode button will automatically...

Страница 29: ...s to be checked for leakage at least once every 12 months according to regulation n 842 2006 This activity has to be covered by qualified personnel only In the case above a maintenance book has to be...

Страница 30: ...el upwards to remove the front panel 2 Grab the handle Then pull the Air filter towards you and slide it down 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse...

Страница 31: ...er Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the DNA filter out to remove it from the slot The DNA filter can be placed in any of the 4 slots beneat...

Страница 32: ...e panel upwards to remove the front panel 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Deodorizing filter out to remove it...

Страница 33: ...pan 2 Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Outdoor unit Clean the heat exchanger on the outside of the unit 2 Clean the heat...

Страница 34: ...off to against cold air when the heat pump is heating Anti protection of internal battery The compressor will be off to protect internal battery when the air conditioner operates in Cool mode Protect...

Страница 35: ...to in Auto Dry mode Timer function does not set Check if you press the Set Cancel button on the remote control after you have set the time Odors permeate in the room during operation Check if the appl...

Страница 36: ...o have either water blow off or drops on the floor HEATING 27 C or less 15 C to 24 C Internal protection triggers and the air conditioner will stop DRYING 18 C to 32 C 10 C to 43 C Condensation may oc...

Страница 37: ...memo _37 ENGLISH...

Страница 38: ...0 www samsung com lu NETHERLANDS 0900 SAMSUNG 0900 7267864 0 10 Min www samsung com nl NORWAY 3 SAMSUNG 7267864 www samsung com no POLAND 0 801 1SAMSUNG 172678 022 607 93 33 www samsung com pl PORTUGA...

Страница 39: ...ner user manual imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register AQV09A Series A...

Отзывы: