Troubleshooting
Samsung Electronics
131
4-3-46
/
COMP Overcurrent error
Outdoor unit display
(INVERTER1 PBA)
(INVERTER2 PBA)
Judgment Method
• Will occur if the overcurrent flowing in the IPM.
• Detected by H/W or S/W
Cause of problem
• COMP. defective.
• Inverter PBA Defective.
1. Cause of problem
Remove the obstacles and check
the status of the installation.
No
Yes
Is the outdoor unit installed properly?
Power Off
Replace Compressor
No
Yes
Is the resistance value
between phase of Compressor wire
(U-V, V-W, W-U) less than 2Ω?
Replace Compressor
No
Yes
Is the resistance between
the body of Compressor and
chassis MΩ?
No
Yes
Does the Compressor
connection wire properly connect
to the compressor?
Check the connection wire
(Check the status of the
connection UVW)
Continue.
4-3 Appropriate Measures for Different Symptom (cont.)
Содержание AM072BXV Series
Страница 141: ...Troubleshooting Samsung Electronics 135 4 3 Appropriate Measures for Different Symptom cont...
Страница 160: ...Samsung Electronics 154 Troubleshooting 4 4 2 Pump down operation cont 4 4 Case study for trouble shoots cont...
Страница 162: ...Samsung Electronics 156 Troubleshooting 4 4 3 Pump out operation cont 4 4 Case study for trouble shoots cont...
Страница 190: ...PBA Diagram and Parts List Samsung Electronics 184 5 8 PF8 Inv Integration J POWER 1 2 3 4 5 6 1 7 8 12 11 10 9...
Страница 192: ...PBA Diagram and Parts List Samsung Electronics 186 5 9 PF8 Inv Integration F POWER 1 2 3 4 5 6 11 10 9 12 1 7 8...
Страница 200: ...Samsung Electronics 194 Wiring Diagram This Document can not be usedwithout Samsung s authorization 6 3 AM162BXVGF AA...
Страница 201: ...Samsung Electronics 195 Wiring Diagram 6 4 AM192BXVGJ AA This Document can not be usedwithout Samsung s authorization...