Samson trovis 5570 Скачать руководство пользователя страница 1

Automation System TROVIS 5500
Room Panel
TROVIS 5570

Mounting and
Operating Instructions

EB 5570 EN

®

Electronics from SAMSON 

Firmware version 1.0x
Edition March 2003

Содержание trovis 5570

Страница 1: ...Automation System TROVIS 5500 Room Panel TROVIS 5570 Mounting and Operating Instructions EB 5570 EN Electronics from SAMSON Firmware version 1 0x Edition March 2003...

Страница 2: ...g lost profits or any other financial loss except the damage was caused by wrongful intent or by gross negligence If an essential term of the contract is breached by negligence SAMSON s liability is l...

Страница 3: ...mode 6 1 4 Setting the data 7 1 4 1 Setting the clock 7 1 4 2 Setting the times of use 8 1 4 3 Setting the temperature set points 9 1 4 4 Setting the party mode 9 2 Start up 10 2 1 Calibrating the roo...

Страница 4: ...Switch over key Is used to switch between the operating and parameter levels Party key Is used to adjust the party timer to prolong or start rated operation Note that you require a slim object such as...

Страница 5: ...ta 1 Clock _ _ _ _ Operating mode When is displayed rated operation When no symbol is displayed reduced operation Times of use 5 Time of use 6 Time of non use Data 2 Room temperature _ _ _ Day night s...

Страница 6: ...tomatic operation will be displayed during times of use no symbol will be dis played during times of non use 6 5 6 Rated operation will be activated during the programmed times of use and reduced op e...

Страница 7: ...the clock Proceed as follows Open the cover Press this key to enter the parameter level The arrow data indicator at the top of the display will point to The display will show the time Press this key...

Страница 8: ...ay will point to and the display will show 1 7 daily Further pressing of this key will toggle through the days of the week 1 Monday 2 Tuesday 7 Sunday Press this key to enter the editing mode The star...

Страница 9: ...the desired temperature set point Press this key to enter the editing mode Edit the temperature set point Confirm the temperature set point Leave the parameter level 1 4 4 Setting the party mode You c...

Страница 10: ...ce Auto Auto automatically searches for a free device bus address in the system Auto automatically searches for a room panel in enabled identifying mode Proceed as follows For the heating and district...

Страница 11: ...ng to a poor control behavior A high precision thermometer will be re quired to determine the reference value Proceed as follows Press the correction key Adjust the determined temperature difference C...

Страница 12: ...26 5 V AC 15 to 36 V DC is to be provided by the customer Connecting to the TROVIS 5576 or TROVIS 5579 Heating and District Heating Controller Refer to Fig 1 5 Technical data 12 EB 5570 EN Electrical...

Страница 13: ...5576 TROVIS 5570 Y1 Y2 0 10V 0 10V 23 22 21 20 19 24 25 26 27 28 29 30 1 2 3 4 5 6 7 8 9 Fig 1 Connecting the TROVIS 5570 Room Panel to the TROVIS 5576 or TROVIS 5579 Heating and District Heating Con...

Страница 14: ......

Страница 15: ......

Страница 16: ...SAMSON AG MESS UND REGELTECHNIK Weism llerstra e 3 60314 Frankfurt am Main Germany Phone 49 69 4009 0 Fax 49 69 4009 1507 Internet http www samson de EB 5570 EN 2003 03...