background image

PS15

PB15

PB15PRO

RACK-MOUNT POWER DISTRIBUTION

Содержание PowerBrite PB15

Страница 1: ...PS15 PB15 PB15PRO RACK MOUNT POWER DISTRIBUTION ...

Страница 2: ...ecep tacles and at the point at which they exit from the unit 11 Unplug this unit during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified personnel Servicing is required when the unit has been damaged in any way such as power supply cord or plug damage or if liquid has been spilled or objects have fallen into the unit the unit has been exposed to rain or...

Страница 3: ...1 784 2201 www samsontech com Table of Contents Introduction 2 PowerBrite Features 3 PS15 Guided Tour Front Panel 4 PS15 Guided Tour Rear Panel 5 PB15 Guided Tour Front Panel 6 PB15 Guided Tour Rear Panel 7 PB15PRO Guided Tour Front Panel 8 PB15PRO Guided Tour Rear Panel 9 Setting Up and Using Your PowerStrip or PowerBrite 10 Appendix A LED Or Incandescent 11 Specifications 12 ...

Страница 4: ...llow us to send you updated information about other Samson products in the future Also be sure to check out our website www samsontech com for complete information about our full product line With proper care and adequate air circulation your PowerStrip PS15 PowerBrite PB15 or PowerBrite PB15Pro will operate trouble free for many years We recommend you record your serial number in the space provid...

Страница 5: ...ciency and minimal noise Front panel re settable 15 amp circuit breaker protects all connected gear An independent dedicated switch with status light for powering the rear panel switched outlets In the PowerBrite PB15 and PowerBrite PB15Pro dual slide out cylinders containing LED light clusters that illuminate all gear underneath with cool clear light In addition there is automatic switching for t...

Страница 6: ...to reduce the load and gently press the circuit breaker in until you hear it click Note It may take a minute to cool before you can reset it 2 Vent Convection cooling is accomplished by the front panel vent holes 3 Unswitched convenience outlet This 3 pin AC outlet is active whenever the PS15 is plugged in regardless of the setting of the Outlets switch see 4 below 4 Outlets switch Use this to tur...

Страница 7: ...ent to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 2 on the previous page 3 Switched AC outlets vertical mount Similar to the AC outlets described in 2 above these are mounted vertically so as to accommodate external transformer AC power adapters 4 Ground Lug Convenient thumb screw for connecting home run grounds ...

Страница 8: ...efore you can reset it 2 Dimmer Use this to adjust the level of the LED light in the slide out Lamps 3 Lamps Contains the PB15 s 5 LED light Use the Dimmer control see 2 above to adjust the brightness of the lamps To turn off the lamp gently slide the lamp back in 4 Vents Convection cooling is accomplished by the front panel vent holes 5 Unswitched convenience outlet This 3 pin AC outlet is active...

Страница 9: ...lets horizontal mount Connect external equipment to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 6 on the previous page 4 Switched AC outlets vertical mount Similar to the AC outlets described in 3 above these are mounted vertically so as to accommodate external transformer AC power adapters 5 Ground Lug Convenient thumb screw for connecting h...

Страница 10: ... in the electrical signal being received by the PowerBrite PB15Pro WARNING Severe voltage swings can cause damage to connected equipment If you see the voltmeter changing drastically or rapidly disconnect the PB15Pro until the source of the problem is identified 5 Vents Convection cooling is accomplished by the front panel vent holes 6 Ammeter This three digit LED meter shows the amount of current...

Страница 11: ...ts horizontal mount Connect external equipment to these standard 3 pin AC outlets which are turned on and off from the front panel Outlets switch see 8 on the previous page 4 Switched AC outlets vertical mount Similar to the AC outlets described in 3 above these are mounted vertically so as to accommodate external transformer AC power adapters 5 Ground Lug Convenient thumb screw for connecting hom...

Страница 12: ...nel Outlets switch so that its status light is lit red This activates all rear panel switched outlets 5 Turn on all connected equipment one at a time If the total load exceeds 15 amps the front panel circuit breaker will trip To reset it unplug one or more devices then press in the front panel circuit breaker 6 You can also use the unswitched front panel convenience outlet for additional temporary...

Страница 13: ...ximately 50 times longer than incandescent ones with a typical life of 100 000 hours as opposed to incandescent lights which rarely last more than about 2 000 hours LED lights are brighter than incandescent ones and when properly arranged they deliver much greater light level The quality of our LED light is similar to daylight while incandescent lights impart a yellowish artificial glow Taking you...

Страница 14: ...ng Voltage 50 A 340 Vac Response Time 1 nanosecond Max Surge Current 6 000 Amps 8 x 20 _s pulse Max Spike Energy 70 Joules per leg Noise Attenuation 20 dB 1 5 MHz to 200 MHz Power Cord Attached 14 gauge LED Light Life Typical 100 000 Hours General Dimensions 19 in w x 7 5 d x 3 5 h 482 mm w x 190 d x 88 h Weight PS15 5 0 lbs 2 27 kg PB15 6 5 lbs 2 95 kg PB15PRO 7 0 lbs 3 18 kg Specifications are s...

Страница 15: ......

Страница 16: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com ...