![Samson 43-6 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/samson/43-6/43-6_mounting-and-operating-instructions_3953126035.webp)
EB 2172 EN
5-7
Installation
Risk of burn injuries due to hot or very cold
components and pipelines.
Depending on the process medium, the regu-
lator and pipelines may get very hot or cold
and cause burn injuries.
Î
Wear protective clothing and safety
gloves.
SAMSON regulators are delivered ready for
use. To test the regulator functioning before
start-up or putting back the regulator into
operation, perform the following tests:
5.4.1 Leak test
The plant operator is responsible for per-
forming the leak test and selecting the test
method. The leak test must comply with the
requirements of the national and internation-
al standards that apply at the site of installa-
tion.
SAMSON's After-sales Service can support
you to plan and perform a leak test for your
plant.
WARNING
!
Tip
1. Slowly open the shut-off valve installed
upstream of the regulator.
2. Apply the required test pressure.
3. Check the regulator for leakage to the at-
mosphere.
4. Check the screw gland of the sensor or
thermowell for leakage.
5.
Depressurize the pipeline section and
regulator.
6. Rework any parts that leak and repeat
the leak test.
5.4.2 Pressure test
The plant operator is responsible for
performing the pressure test.
SAMSON's
After-sales Service can support you to plan
and perform a pressure test for your plant.
Risk of regulator damage due to a sudden
pressure increase and resulting high flow ve
-
locities.
Î
Slowly open the shut-off valves.
Note
NOTICE
!
Содержание 43-6
Страница 16: ...2 4 EB 2172 EN Markings on the device...
Страница 26: ...3 10 EB 2172 EN Design and principle of operation...
Страница 44: ...8 4 EB 2172 EN Malfunctions...
Страница 54: ...11 2 EB 2172 EN Removal...
Страница 56: ...12 2 EB 2172 EN Repairs...
Страница 58: ...13 2 EB 2172 EN Disposal...
Страница 62: ...14 4 EB 2172 EN Certificates...
Страница 66: ...15 4 EB 2172 EN Annex...
Страница 67: ......