11 = Timeout
17 = Initialization status: determination of mechanical stops
19 = Initialization status: determination of minimum transit times
20 = Initialization aborted due to activated forced venting option
30 = Zero error
254 = Successful
Calibration
alarm message
SELF_CALIB_WARNING (M)
States:
Default:
Additional alarm messages of the initiated calibration procedure.
0 = Undetermined
13 = Wrong selection of rated travel or transmission
15 = Air leakage of pneumatic system (during initialization)
254 = Successful
255 = No valid data at the application
0
Characteristic selection
CHARACT
States:
Default:
Characteristic selection for the creation of assignments between the reference variable
and valve travel/angle range.
0 = Linear
1 = Equal percentage
2 = Equal percentage reverse
3 = Customized (supported by a future Firmware version)
4 = SAMSON butterfly control valve: linear
5 = SAMSON butterfly control valve: equal percentage
6 = Vetec rotary plug valve: linear
7 = Vetec rotary plug valve: equal percentage
0
Characteristic type
CHARACT_TYPE
Text field (32 characters) for a description of the adjusted characteristic.
Coldstart
FACTORY_RESET
States:
Default:
Command for reset to default values.
0 = No action
1 = Reset application to default values. All device data are reset to default values. The
positioner moves to fail-safe position and must be reinitialized. Only the device
identification parameters are retained.
2 = Reset device identification to default values. All device identification parameters
are reset. Application parameters are retained.
0
Controlled variable x
READBACK
Current position with status
Controlled variable x in % related to the travel/angle of rotation range
Correction value
OUT
Correction value calculated by the function block from the set point in [mm] or
[degree].
This value can be entered in the "local override"(LO) operating mode.
Date last calibration
DEVICE_CALIB_DATE
Indicates the last calibration date of the field device.
Date last configuration
DEVICE_CONFIG_DATE
Indicates the last configuration date of the field device.
50
EB 8382-1 EN
List of parameters
Содержание 3785 series
Страница 69: ...EB 8382 1 EN 69...
Страница 70: ...70 EB 8382 1 EN...
Страница 71: ...EB 8382 1 EN 71...
Страница 72: ...72 EB 8382 1 EN...
Страница 73: ...EB 8382 1 EN 73...
Страница 74: ...74 EB 8382 1 EN...
Страница 75: ...EB 8382 1 EN 75...
Страница 76: ...76 EB 8382 1 EN...
Страница 77: ...EB 8382 1 EN 77...
Страница 78: ...78 EB 8382 1 EN...
Страница 79: ...EB 8382 1 EN 79...