EB 2551-2 EN
9-3
Servicing
Removing the filter
1. Put the regulator out of operation (see
the 'Decommissioning' section).
2. Unscrew the strainer stopper (13, width
across flats 19) including seal (50).
3.
Remove the filter (42) and clean it, if nec
-
essary.
Installing the filter
1.
Insert new or cleaned filter (42).
2. Place a new seal (50) on the strainer
stopper (13).
3. Screw the strainer stopper (13) into the
body of the pilot valve. Observe the
specified tightening torques (see 'Tighten
-
ing torques' in the Annex).
50
13
42
13 Strainer stopper
42 Filter
50 Seal
Fig. 9-1:
Pilot valve
The order numbers of the seal and the filter
are listed under 'Accessories' in the Annex.